Leabhar-stiùiridh ENTTEC 73539 DIN PIXIE

ENTTEC 73539 DIN PIXIE Instruction Manual

ENTTEC-LOGO

ENTTEC 73539 DIN PIXIE

ENTTEC-73539-DIN-PIXIE-FIG-1

Fiosrachadh toraidh

Sònrachaidhean:

  • Stiùireadh airson cruthachadh protocol gnàthaichte
  • Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
  • Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2

Stiùireadh airson cleachdadh bathar

Ro-ràdh:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.

Riatanasan rèiteachaidh:

  • Datasheet of the desired pixel fixture
  • Computer to access the device settings page
  • For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
  • For DIN PIXIE: EMU Software for configuration

Guide to Custom Protocol Creation:

  1. Verify datasheet for compatible pixel protocol
  2. Navigate to the Device’s User Interface to enablethe  custom protocol feature
  3. Adjustthe  pixel fixture’s data voltage timing viathe  web interface based othe n datasheet

Step 1: Verify Datasheet for Compatible Protocol

  1. Check the data transmission method from the datasheet
  2. Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
  3. Choose a supported protocol with a similar data transmission method

FEAR-TATHAICH CHOITCHEANN

Tha cruthachadh protocol gnàthaichte ri fhaicinn anns na riaghladairean piogsail ENTTEC a leanas:

SKU Bathar Tionndadh Firmware
73539 DIN PIXIE V2.0 no nas àirde
70067 MINI PIXELATOR V2.0 no nas àirde
70068 PIXELATOR MINI MK2 V1.0 no nas àirde
71521 OCTO MK2 V4.0 no nas àirde
71522 OCTO MK3 V1.0 no nas àirde

RO-RÀDH

  • ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
  • Leigidh am feart seo le luchd-cleachdaidh an voltage àm stèidhichte air na protocolaidhean le taic ma tha an dòigh tar-chuir dàta a rèir gin de na protocolaidhean le taic againn.
  • Tha an sgrìobhainn seo a’ toirt seachad stiùireadh rèiteachaidh airson protocol piogsail àbhaisteach a chruthachadh agus na slatan-tomhais a dhearbhadh.

RIAGHAILTEAN SETUP

Tha feum air na leanas gus protocol gnàthaichte a chruthachadh:

  1. Duilleag dàta: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
  2. Inneal: Use a computer to access the device settings page.
  3. For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
  4. For DIN PIXIE: Use the EMU Software for configuration.

STIÙIREADH GU CRUTHACHADH PROTOCOL CUSTOM

Leigidh am feart seo le luchd-cleachdaidh an dàta atharrachadhtage timing to meet specific protocol needs. To create a custom protocol:

  1. Dearbhaich an duilleag-dàta airson a’ phròtacal piogsail co-fhreagarrach.
  2. Seòl gu eadar-aghaidh cleachdaiche an uidheim gus am feart pròtacal gnàthaichte a chomasachadh.
  3. Atharraich dàta an tàmh-àirneis piogsail voltage ùine tron web eadar-aghaidh a rèir dàta an neach-dèanamh.

Ceum 1: Dearbhaich an duilleag-dàta airson a 'phròtacal co-fhreagarrach

  1. Dearbhaich an dòigh tar-chuir dàta den phròtacal a tha thu ag iarraidh bhon duilleag-dhuilleag.
    1. The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
      • Is e an dòigh as cumanta dàta a chuir a-mach às aonais pìosan a bharrachd (me, D1-D2-D3…Dn).
        Example: Fiosrachadh air a ghlacadh bho dhuilleag-dàta WB2812B

        ENTTEC-73539-DIN-PIXIE-FIG-2

      • Tha cuid de phròtacalan, leithid TM1814, a’ toirt a-steach dàta a bharrachd aig an aghaidh (me, C1-C2-D1-D2…Dn).
        Example: Fiosrachadh air a ghlacadh o chlàr-taice TM1814

        ENTTEC-73539-DIN-PIXIE-FIG-3

  2. Ainmich am protocol maidsidh le taic bhon inneal (no tagh bhon fhear gu h-àrd example) that shares the same data transmission method as your desired pixel protocol.
  3. Lean air adhart gu Ceum 2 airson tuilleadh rèiteachaidh.

Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)

  1. Access to the OCTO/PIXELATOR MINI web eadar-aghaidh
    1. Tha Google Chrome air a mholadh mar an web browser to access the OCTO/PIXELATOR MINI’s web eadar-aghaidh.
    2. Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC weblàrach-lìn www.enttec.com gus an aplacaid a luchdachadh sìos.
    3. After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

      ENTTEC-73539-DIN-PIXIE-FIG-4
      Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
      See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.

  2. Navigate to the Settings page – Output Setting.
    Rach don toradh far a bheil an tàmh-àirneis piogsail a tha thu ag iarraidh ceangailte ris. Tagh protocol piogsail bhon liosta tuiteam-sìos a tha a’ roinn an aon dòigh tar-chuir a chaidh a dhearbhadh ann an Ceum 1.

    ENTTEC-73539-DIN-PIXIE-FIG-5

  3. Enable Custom protocol (Continue to Step 3)
    Cuir an comas am bogsa diog ‘Custom’ gus faighinn chun dàta voltage suidheachadh ùine. Untic gus am pròtacal gnàthaichte a chur à comas.

    ENTTEC-73539-DIN-PIXIE-FIG-6

Airson DIN PIXIE

  1. Ceangail DIN PIXIE ri coimpiutair a’ cleachdadh USB Type-B.
  2. Cuir air bhog bathar-bog EMU.
  3. Dèan scan airson an inneal agus cliog air Conf an lorg DIN PIXIE.

    ENTTEC-73539-DIN-PIXIE-FIG-6

  4. Enable Custom Protocol (Continue to Step 3)
    Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.

    ENTTEC-73539-DIN-PIXIE-FIG-8

Ceum 3: Suidhich àbhaisteach voltage àm

  1. Maids an voltage àm air duilleag-dàta a’ phròtacal a tha thu ag iarraidh. Feumaidh Custom Protocol 4 cuir a-steach gus dàta a chrìochnachadh voltage atharrachadh ùine:
    Voltage Timing Definition
    Bit 0 Àrd-ùine (T0H) Tha an voltage ùine àrd a dhìth airson còd 0.
    Bit 1 Àrd-ùine (T1H) Tha an voltage ùine àrd a dhìth airson còd 1.
    Overall Bit Time: An vol iomlantage time for a single bit.

    Lower limit = T0H+T0L

    Upper limit = T1H+T1L

    Ath-shuidheachadh Àm An vol iomlantage ùine ìosal a dh’ fheumar gus an tar-chuir dàta eadar gach baidse dàta ath-shuidheachadh.

    ENTTEC-73539-DIN-PIXIE-FIG-9

  2. Duilleag-dàta – Data voltagagus fiosrachadh mu àm Example
    Bhon stòr-dàta WB2818B
    • Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage raon-ama.
    • Lìon an voltage raon ùine anns an raon àbhaisteach ann an Roghainnean Toraidh.

      ENTTEC-73539-DIN-PIXIE-FIG-10

CUDROMACH

  • ENTTEC recommends taking the median value of the range for the start.
  • Feumaidh an neach-cleachdaidh na roghainnean SAVE airson an luach atharraichte a thoirt gu buil.
  • Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
  • ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
  • Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.

COMHCHRUINNEACHADH

  • Sheall an iùl seo mar a stèidhicheas tu protocol àbhaisteach airson innealan ENTTEC iomchaidh agus thug e seachad eòlas teignigeach air dearbhadh duilleag-dàta nan tàmh-àirneisean piogsail a tha thu ag iarraidh.
  • Le bhith a’ leantainn nan ceumannan seo, faodaidh luchd-cleachdaidh protocol piogsail àbhaisteach a chruthachadh nach lorgar air an liosta tuiteam-sìos gun a bhith a’ feitheamh ri taic theicnigeach no foillseachadh firmware ùr. Ma tha ceistean agad no ma tha duilgheadas agad am fiosrachadh ceart a lorg, cuir fios chun sgioba taic càirdeil againn aig na h-oifisean ionadail.

Ceistean Cumanta

How do I access the device settings page on my computer?

You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web bhrabhsair.

Can I create a custom protocol without the datasheet?

It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.

Sgrìobhainnean/Goireasan

PDF thumbnail73539 DIN PIXIE
Instruction Manual · DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE

Faighnich Ceist

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Faighnich Ceist