1. Ro-ràdh
The FNIRSI FPM-02 is a high-precision 3-in-1 environmental monitor designed for measuring illuminance (lux), temperature, and humidity. It features a 2-inch color display for clear data visualization and is suitable for various professional applications including office lighting assessment, horticulture, laboratories, and photography studios.
2. Dè tha sa bhogsa
- FNIRSI FPM-02 Environmental Monitor
- Càball USB
- Cùis Giùlain
- Leabhar-làimhe cleachdaiche
3. Prìomh fheartan
- Tomhas 3-ann-1: Monitors Lux, temperature, and humidity simultaneously.
- Sgrion dath 2-òirleach: High-definition display with light and dark theme modes for optimal readability.
- Real-time Data & Curve Recording: Visualizes environmental changes over time.
- Adjustable Alarm Thresholds: Alerts users when measurements exceed set values.
- Fast SampÌre ling: 20Hz (50ms) for real-time monitoring.
- Dual-language Interface: Supports English and Chinese.
- Built-in Sleep Mode & Data Logging: Enhances battery efficiency and usage tracking.

Figure 1: FNIRSI FPM-02 Environmental Monitor with key features highlighted on its color screen.
4. Suidhich
4.1 A’ cur cosgais air an inneal
- Connect the provided USB cable to the FNIRSI FPM-02's charging port.
- Cuir ceann eile a’ chàball USB a-steach do inneal-atharrachaidh cumhachd USB àbhaisteach (nach eil air a ghabhail a-steach) no do phort USB coimpiutair.
- The device will indicate charging status on its screen. A full charge typically takes approximately 2-3 hours.
4.2 A’ cur cumhachd air/dheth
- To power on: Press and hold the Power button (usually located on the side or front panel) until the screen illuminates.
- Gus an inneal a chuir dheth: Brùth is cum sìos am putan Cumhachd gus an dùin e sìos.
5. Stiùireadh Obrachaidh
5.1 A’ seòladh an eadar-aghaidh
The FPM-02 features a user-friendly interface with a 2-inch HD color screen. Use the navigation buttons (up, down, left, right, OK/Enter) to move through menus and select options. The device supports both English and Chinese languages, which can be selected in the settings menu.
5.2 Taking Measurements (Illuminance, Temperature, Humidity)
Upon powering on, the device typically defaults to the main measurement screen, displaying real-time values for illuminance (Lux/FC), temperature (°C/°F), and relative humidity (%).
- Soillseachadh: Ensure the light sensor (located at the top of the device) is unobstructed and pointed towards the light source or area to be measured. The device will display the light intensity in LUX or FC.
- Teòthachd & Taiseachd: The internal sensors continuously monitor ambient temperature and humidity. Allow a few minutes for readings to stabilize after significant environmental changes.
5.3 Real-time Data and Curve Recording
The device can display real-time data and record changes over time, presenting them as a curve. Access this feature through the main menu to visualize trends and fluctuations in environmental conditions.
5.4 Setting Alarm Thresholds
You can set custom alarm thresholds for Lux, temperature, and humidity. If a measured value exceeds or falls below the set threshold, the device will trigger an alert. Refer to the device's settings menu to configure these thresholds.
5.5 Sleep Mode and Data Logging
To conserve battery, the device features a configurable sleep mode. It also includes data logging capabilities, allowing you to store measurement data for later review and analysis. Consult the user manual for detailed instructions on activating and managing these functions.
6. Cumail suas
- Glanadh: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents. Ensure the light sensor and display are kept clean for accurate readings.
- Stòradh: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.
- Cùram Bataraidh: Avoid fully discharging the lithium battery frequently. Recharge the device when the battery level is low.
7. A ’dèanamh trioblaid
| Trioblaid | Adhbhar a dh’fhaodadh a bhith ann | Fuasgladh |
|---|---|---|
| Chan eil cumhachd aig an inneal. | Bataraidh ìosal no crìon. | Cuir cosgais air an inneal a’ cleachdadh a’ chàball USB a chaidh a thoirt seachad. |
| Leughaidhean neo-mhearachdach. | Sensor obstructed or dirty; device not calibrated. | Clean sensors. Ensure proper placement. If issues persist, contact support. |
| Tha an sgrion neo-fhreagairt. | Software glitch; extreme temperature. | Restart the device. Ensure operating within specified temperature range. |
8. Sònrachaidhean Teicnigeach
| Paramadair | Luach |
|---|---|
| Modail Àireamh | FPM-02 |
| Raon Solais | 0–1000 / 9999 / 99990 LUX; 10–1000 / 1000 / 10000 FC |
| Fuasgladh Soillseachadh | 0.1 LUX (0–1000); 0.1 FC (10–1000) |
| Cruinneas Soillseachadh | ±(3% + 5 LUX) with standard incandescent lamp (2854°K); ±(6% + 5 LUX) for other light sources |
| Sampling Ùine | 20Hz (50ms) |
| Taisbeanadh | 2″ HD Color Screen |
| Stòr cumhachd | Bataraidh litiam 3.7V / 1500mAh |
| Meudan inneal | 63 × 28 × 182 mm |
| Cuideam | 205g |
| Dath | Dubh & Gorm |
| Dùthaich Tùs | Sìona |
9. Barantas agus Taic
This FNIRSI FPM-02 Environmental Monitor comes with a standard manufacturer's warranty. Please refer to the warranty card included in your package for specific terms and conditions.
Airson taic theicnigeach, cuideachadh le fuasgladh dhuilgheadasan no tagraidhean barantais, cuir fios chun neach-reic no an neach-dèanamh gu dìreach. Cùm do chuidhteas ceannach mar dhearbhadh ceannach.