OLMO OS-24SRW-230VI & OS-SR24-230VO
OLMO 24,000 BTU Ductless Mini Split Air Conditioner & Heat Pump
Instruction Manual for Models OS-24SRW-230VI & OS-SR24-230VO
19.5 SEER2 – 230V Inverter System – Pre-Charged with R-32
Ro-ràdh
This manual provides essential information for the installation, operation, and maintenance of your OLMO 24,000 BTU Ductless Mini Split Air Conditioner and Heat Pump. This system is designed to provide efficient heating and cooling for various spaces, featuring a 19.5 SEER2 rating and a 230V inverter system. It comes pre-charged with R-32 refrigerant and includes a 16-foot installation kit. Please read this manual thoroughly before installation and use to ensure proper function and safety.

Figure 1: Complete OLMO Mini Split System with Indoor and Outdoor Units, Remote, and Smart App.
Co-phàirtean air an toirt a-steach
Your OLMO Mini Split system includes the following components for a comprehensive installation:
- OLMO 24,000 BTU Single Zone Outdoor Condenser: 19.5 SEER2, 230V.
- One Wall Mount Air Handler: Aonad a-staigh.
- Smart Kit: For controlling your system via smartphone app.
- 16FT Insulated Copper Line Set: Pre-flared for easier connection.
- 16FT Communication Cable: For connecting indoor and outdoor units.
- 16FT Drainage Extension: Designed for no-kink performance.
- Smachd air astar: Airson obrachadh goireasach.
- Small Accessories: Various parts for professional installation.

Figear 2: Mionaideach view of included components for the OLMO Mini Split system.
Stàladh agus stàladh
Cudromach: This is not a DIY system. Professional installation is required to ensure proper function, safety, and warranty validity. The system comes pre-charged with R-32 refrigerant.
Outdoor Unit Placement and Connections
The outdoor condenser unit should be placed on a stable, level surface or mounted securely using appropriate brackets. Ensure adequate clearance around the unit for proper airflow and maintenance. The 16FT insulated copper line set, communication cable, and drainage extension are provided for connecting the indoor and outdoor units.

Figure 3: OLMO Outdoor Condenser Unit.

Figure 4: No-Kink Drainage Extension included with the system.
Stàladh aonad a-staigh
The indoor air handler should be mounted on a wall in a location that allows for optimal air distribution and minimal obstruction. Consult with your professional installer for the best placement in your space.

Figure 5: OLMO Indoor Air Handler Unit.
Stiùireadh Obrachaidh
Your OLMO Mini Split system can be operated using the included remote control or via the smartphone app (Smart Kit required).
Gnìomhan smachd iomallach
The remote control allows you to adjust various settings for optimal comfort:
- Cumhachd air / dheth: Cuiridh e an aonad an gnìomh no dheth e.
- Taghadh Modh: Choose between Cool, Heat, Fan, Auto, and Dry modes.
- Atharrachadh teòthachd: Set your desired temperature.
- Luas an neach-leantainn: Adjust the fan speed (multiple settings available).
- Gnìomh swing: Control the louver movement for air distribution.
- Modh cadail: Optimizes settings for comfortable sleep.
- Modh Turbo: A’ toirt seachad fuarachadh no teasachadh luath.
- Modh eco: Obrachadh a shàbhaileas lùth.
- Uaireadair: Set schedules for turning the unit on or off.
- Modh fèin-ghlan: Initiates a self-cleaning cycle for the indoor unit.
- Taisbeanadh LED: Turn the unit's LED display on or off for undisturbed sleep.
Smart Control (App)
With the included Smart Kit, you can control your OLMO Mini Split system from anywhere using your smartphone. Download the official OLMO remote app from your device's app store:

Figure 6: Download the OLMO Remote App for Smart Control.
Prìomh fheartan
- Powerful & Efficient Climate Control: Provides high-performance heating and cooling for large rooms, open spaces, and light commercial areas.
- All-Season Comfort: Operates efficiently in a wide temperature range, ensuring consistent comfort in both summer and winter. Ideal for garages, basements, additions, and converted living spaces.
- Obrachadh sàmhach: Designed for quiet indoor performance, minimizing noise while maximizing airflow.
- Dealbhadh caol: Modern aesthetics allow the ductless unit to fit seamlessly into your room.
- Astar caochlaideach: Optimizes energy consumption and comfort.

Figure 7: OLMO Mini Split Unit in a modern interior setting.
Sònrachaidhean
| Sònrachadh | Luach |
|---|---|
| Ainm Brand | ELM |
| Fiosrachadh modail | OS-24SRW-230VI & OS-SR24-230VO |
| Meudan toraidh | 40 x 48 x 40 òirleach |
| Àireamh Modail Nì | OS-24SRW-230VI & OS-SR24-230VO |
| Èifeachdas | Àrd-èifeachdas |
| Comas | 2 Tunna (24,000 BTU) |
| Seòrsa stàlaidh | Siostam roinnte |
| Factor foirm | Mini-roinneadh |
| Feartan sònraichte | Silent Mode, Variable Speed |
| Dath | Geal |
| Voltage | 230 bholt (AC) |
| Co-phàirtean air an toirt a-steach | Comes as a Combo Set |
| Cumhachd fuarachaidh | 24000 Aonadan Teirmeach Bhreatainn |
| Co-mheas Èifeachdais Lùtha Ràitheil (SEER) | 19.5 |
| Reothadair | R-32 |
| Stòr cumhachd | Electric Corded |

Figure 8: Comprehensive Technical Specifications.
Cumail suas
Regular maintenance is crucial for the longevity and efficient operation of your OLMO Mini Split system. While professional servicing is recommended annually, some basic tasks can be performed by the user:
- Glanadh sìoltachain: The indoor unit's air filters should be cleaned regularly (e.g., monthly, or more frequently with heavy use) to maintain airflow and air quality. Refer to your professional installer's instructions for filter removal and cleaning procedures.
- Outdoor Unit Clearance: Ensure the outdoor unit remains free of debris, leaves, and other obstructions that could impede airflow.
- Drainage Line Check: Periodically inspect the drainage line for any blockages or kinks to prevent water backup.
Fuasgladh thrioblaidean
If you experience any issues with your OLMO Mini Split system, please consult your professional installer or contact technical support. Common issues and initial checks may include:
- Gun chumhachd: Check the circuit breaker and ensure the unit is properly connected to its power source.
- Fuarachadh/Teasachadh Neo-iomchaidh: Verify temperature settings, ensure filters are clean, and check for any obstructions to airflow.
- Fuaimean neo-àbhaisteach: Minor operational sounds are normal, but loud or persistent noises may indicate an issue requiring professional inspection.
- Uisge ag aoidion: Check the drainage line for blockages or improper slope.
For complex issues, always contact a qualified HVAC technician.
Barantas agus Taic
Your OLMO Mini Split system comes with a limited warranty:
- Compressor: Barantas 5 Bliadhnaichean Earranta
- Pàirtean: Barantas 2 Bliadhnaichean Earranta
Free US-based technical support is available should you ever need assistance. Please refer to your warranty documentation for full terms and conditions.

Figure 9: Certifications and Warranty Information.