Aunnhon Breath Ketosis Meter

Aunnhon Breath Ketosis Meter User Manual

Model: Breath Ketosis Meter

1. Ro-ràdh

The Aunnhon Breath Ketosis Meter is a portable device designed to measure ketone levels in your breath, providing an indication of your body's ketosis state. This device utilizes advanced semiconductor sensors to detect acetone concentration, offering a convenient and non-invasive method for monitoring ketosis without the need for blood or urine tests.

This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your Breath Ketosis Meter. Please read it thoroughly before first use to ensure accurate results and safe operation.

Aunnhon Breath Ketosis Meter with multiple mouthpieces

Image 1.1: Aunnhon Breath Ketosis Meter and included mouthpieces.

Diagram of the Breath Ketosis Meter components

Image 1.2: Labeled components of the Breath Ketosis Meter, including mouthpiece, LCD display, power button, vent hole, speakers, and battery compartment.

2. Fiosrachadh Sàbhailteachd

  • This device is intended for personal monitoring of breath ketone levels and should not be used for medical diagnosis or treatment. Consult a healthcare professional for any health concerns.
  • Cùm an inneal a-mach à ruigsinn chloinne.
  • Na cuir an inneal fo theodhachd anabarrach, solas dìreach na grèine, no taiseachd àrd.
  • Seachain an inneal a leigeil sìos no buaidh làidir a thoirt air.
  • Use only the specified battery type (2*AA batteries, not included). Ensure correct polarity when inserting batteries.
  • Cha deach aithrisean a thaobh stuthan daithead a mheasadh leis an FDA agus chan eilear an dùil a bhith a’ lorg, a’ làimhseachadh, a’ leigheas, no a’ casg galair no suidheachadh slàinte sam bith.

3. Suidhich

3.1 A ’stàladh bataraidhean

  1. Fosgail còmhdach roinn a’ bhataraidh a tha suidhichte air cùl an inneil.
  2. Insert two (2) AA batteries (not included), ensuring the correct positive (+) and negative (-) polarity.
  3. Dùin an còmhdach roinn bataraidh gu tèarainte.

3.2 Attaching a Mouthpiece

Attach one of the provided mouthpieces to the designated port on the side of the device. Ensure it is firmly seated.

3.3 Initial Device Exhaustion (First Use Only)

Before your first actual test, the device requires an initial 'exhaustion' process to prepare the sensor for accurate readings. This procedure should be performed 1-2 times without blowing into the device.

  1. Brùth agus cum sìos am putan cumhachd airson 2 dhiog gus an inneal a thionndadh.
  2. The device will display a 20-second countdown. Allow this countdown to complete.
  3. Once the countdown finishes, turn the device off.
  4. Repeat steps 1-3 one or two more times.

After completing the initial exhaustion, the device is ready for regular use.

Four-step guide for using the Breath Ketosis Meter

Image 3.1: Visual guide for device setup and operation, showing battery installation, preheat countdown, blowing, and result display.

4. Stiùireadh Obrachaidh

4.1 Performing a Ketone Breath Test

  1. Ensure a clean mouthpiece is attached.
  2. Brùth agus cum sìos am putan cumhachd airson 2 dhiog gus an inneal a thionndadh.
  3. The device will display a 20-second countdown as it warms up.
  4. Once the countdown completes and "START" appears on the screen, immediately take a deep breath and blow steadily into the mouthpiece for 5-6 seconds.
  5. The device will analyze your breath, and the result will be displayed on the LCD screen for 10 seconds.

4.2 Mìneachadh Thoraidhean

The device measures ketone levels in Parts Per Million (PPM) from 0.0 to 99 PPM. It also features three LED indicators:

  • Solas Uaine: Indicates a successful ketosis reading.
  • Solas Dearg: Indicates an unsuccessful ketosis reading or an error during the test.
  • Solas òmar: A’ nochdadh cumhachd bataraidh ìosal.
LED indicator meanings for the Breath Ketosis Meter

Image 4.1: Explanation of LED indicators: Green for successful reading, Red for unsuccessful reading, and Amber for low battery.

4.3 Important Considerations for Accurate Readings

  • There can be a time lag before ketone levels drop after consuming high-carbohydrate foods. Readings may still be high during this period.
  • The duration of this lag varies per individual and depends on how long you have been following a ketogenic lifestyle.
  • For consistent results, try to test at the same time each day, ideally first thing in the morning before eating or drinking.

5. Cumail suas

5.1 A ’glanadh an inneal

Wipe the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water.

5.2 Mouthpiece Replacement

The device comes with multiple reusable mouthpieces. For hygiene, it is recommended to replace the mouthpiece regularly, especially if sharing the device or if the mouthpiece appears worn or damaged.

5.3 Ath-nuadhachadh bataraidh

When the Amber LED light illuminates, it indicates low battery power. Replace both AA batteries promptly to ensure accurate readings and proper device function. Refer to Section 3.1 for battery installation instructions.

6. A ’dèanamh trioblaid

  • Chan eil an inneal a’ tionndadh air:
    Dèan cinnteach gu bheil na bataraidhean air an cur a-steach gu ceart leis a’ phòlaireachd cheart. Cuir bataraidhean ùra nan àite ma tha iad air an leigeil ma sgaoil.
  • Red Light (Unsuccessful Reading):
    This can occur if you did not blow for the required 5-6 seconds, or if the blowing was not steady. Ensure a continuous, steady breath. Repeat the test.
  • Leughaidhean neo-chunbhalach:
    Ensure the initial exhaustion process was performed correctly. Avoid eating, drinking, or smoking for at least 30 minutes before testing. Ensure you are blowing consistently for the specified duration. Environmental factors like strong odors can also affect readings.
  • Amber Light (Low Battery):
    Cuir an dà bataraidh AA nan àite sa bhad.

7. Sònrachaidhean

ModailBreath Ketosis Meter
BrandAunnhon
Raon Tomhais0.0 - 99 PPM (Parts Per Million)
Stòr cumhachd2 x Bataraidhean AA (gun a thoirt a-steach)
Meudan5.31 x 3.54 x 1.73 òirleach
Cuideam4.16 unnsa
DèanadairAunnhon
Dimensions of the Breath Ketosis Meter

Image 7.1: Physical dimensions of the Aunnhon Breath Ketosis Meter.

8. Barantas agus Taic

For warranty information or technical support, please refer to the contact details provided with your product packaging or visit the official Aunnhon weblàrach. Cùm do chuidhteas ceannach mar dhearbhadh ceannach.