Aramox TM619H-2

Aramox TM619H-2 Electronic Time Control Switch

Leabhar-làimhe cleachdaiche

1. Ro-ràdh

This manual provides detailed instructions for the installation, operation, and maintenance of your Aramox TM619H-2 Electronic Time Control Switch. Please read this manual thoroughly before using the device to ensure proper function and safety. Keep this manual for future reference.

2. Fiosrachadh Sàbhailteachd

  • Always disconnect power before installation or maintenance to prevent electric shock.
  • Bu chòir do dhealanair teisteanasach no neach eòlach an stàladh a dhèanamh.
  • Ensure the wiring connections are secure and comply with local electrical codes.
  • Do not expose the device to excessive moisture, dust, or extreme temperatures.
  • The device is designed for indoor use unless otherwise specified.

3. Toradh thallview

The Aramox TM619H-2 is a digital time control switch designed for precise scheduling of electrical devices. It features an LCD digital display and supports both 24-hour and 12-hour time systems. This model operates on 12V DC and includes a memory backup function to retain programming during power interruptions (requires a 3V lithium battery, not included).

Prìomh fheartan:

  • Digital LCD display for clear time and program viewing.
  • Supports 24-hour and 12-hour time systems.
  • Programmable ON/OFF events.
  • Memory backup during power outages (with installed battery).
  • Manual override function.

Co-phàirtean:

The device consists of a main body with an LCD display and control buttons on the front, and wiring terminals on the back.

Aghaidh view of the Aramox TM619H-2 Electronic Time Control Switch showing the LCD display and control buttons.

Figear 1: Aghaidh view of the TM619H-2 timer switch, displaying the LCD screen and various control buttons such as CLOCK, TIMER, DAY, HOUR, MIN, and MANUAL.

4. Sònrachaidhean

FeartSònrachadh
Modail BatharTM619H-2
Bathar StuthABS
Seòrsa TaisbeanaidhTaisbeanadh didseatach LCD
Obair VoltageDC12V
Tricead50/60Hz
Rangachadh làithreach30A
Battery (for memory)Lithium battery 3V (not included)
Meudan toraidh3.15 x 3.15 x 1.97 òirleach (8 x 8 x 5 cm)
Cuideam nì4.3 unnsa (122 gram)

5. Suidhich

5.1. Stàladh Bataraidh (airson Cùl-taic Cuimhne)

The TM619H-2 requires a 3V lithium battery (e.g., CR2032, not included) for memory backup. This battery ensures that your programmed settings are retained during power outages. Locate the battery compartment, insert the battery with the correct polarity, and close the compartment.

5.2. Sreap

The timer switch is designed for panel assembly. Secure the device in a suitable enclosure or panel cutout using appropriate mounting hardware (not included).

5.3. Sreangachadh

Refer to the wiring diagram on the back of the device and the images below for correct connections. Ensure all connections are tight and insulated.

Air ais view of the Aramox TM619H-2 Electronic Time Control Switch showing the wiring terminals labeled 1 to 5.

Figear 2: Air ais view of the TM619H-2 timer switch, illustrating the input and output terminals for wiring.

Comparison of new and old model wiring diagrams for the TM619H-2 timer switch.

Figure 3: Comparison of wiring configurations for new and old versions of the TM619H-2 model. Always refer to the diagram on your specific unit.

General Wiring Guide:

  • Input Power (DC12V): Connect your 12V DC power supply to the designated input terminals (typically labeled 'INPUT' or 'LINE').
  • Toradh Luchdaidh: Connect the device you wish to control to the output terminals (typically labeled 'OUTPUT' or 'LOAD'). The timer acts as a switch for this load.
  • Ensure the load's current draw does not exceed the timer's maximum rating of 30A.

6. Stiùireadh Obrachaidh

6.1. Initial Power-Up and Reset

Upon first power-up or after battery installation, the display may show random characters. Press the R (Reset) button (usually a small recessed button requiring a pointed object) to clear all settings and initialize the timer.

6.2. A 'suidheachadh Àm an-dràsta

  1. Brùth an CLOC button and hold it.
  2. Fhad 'sa tha e a' cumail CLOC, brùth LATHA gus latha làithreach na seachdain a shuidheachadh.
  3. Fhad 'sa tha e a' cumail CLOC, brùth UAIR gus an uair làithreach a shuidheachadh.
  4. Fhad 'sa tha e a' cumail CLOC, brùth MIN gus am mionaid làithreach a shuidheachadh.
  5. Sgaoil an CLOC putan. Tha an t-àm air a shuidheachadh a-nis.

6.3. Switching 12/24-Hour System

To switch between 12-hour (AM/PM) and 24-hour formats, press the CLOC putan agus an uairsin an TIMER putan aig an aon àm.

6.4. Programming ON/OFF Events

The TM619H-2 allows you to set multiple ON/OFF programs. Follow these steps:

  1. Brùth an TIMER putan aon uair. Seallaidh an taisbeanadh “1 ON”.
  2. Brùth LATHA to select the day(s) for this ON event (e.g., Mon-Fri, Sat-Sun, every day, specific day).
  3. Brùth UAIR to set the desired hour for the ON event.
  4. Brùth MIN to set the desired minute for the ON event.
  5. Brùth an TIMER button again. The display will show "1 OFF".
  6. Repeat steps 2-4 to set the day(s), hour, and minute for the corresponding OFF event.
  7. Lean air adhart a 'bruthadh TIMER to cycle through other program settings (2 ON, 2 OFF, etc.).
  8. Às dèidh dhut na prògraman uile a tha thu ag iarraidh a shuidheachadh, brùth air a’ phutan CLOC brùth air a’ phutan gus am modh prògramaidh fhàgail agus tilleadh chun taisbeanadh ùine làithreach.

6.5. Stiùireadh làimhe

Tha an LAOIDH button allows you to override the programmed settings temporarily. Pressing this button cycles through different modes:

  • AIR: The output is continuously ON, ignoring programs.
  • AUTO AIR: The output is currently ON and will follow the next programmed OFF event.
  • AUTO OFF: The output is currently OFF and will follow the next programmed ON event.
  • OFF: The output is continuously OFF, ignoring programs.

Select "AUTO ON" or "AUTO OFF" for the timer to resume automatic operation based on your programs.

7. Cumail suas

  • Glanadh: Sguab an inneal le clò bog, tioram. Na cleachd innealan-glanaidh sgrìobach no fuasglaidhean.
  • Ath-nuadhachadh bataraidh: If the display becomes dim or programs are lost frequently during power interruptions, the 3V lithium backup battery may need replacement. Follow the battery installation steps in Section 5.1.
  • Sgrùdadh: Thoir sùil bho àm gu àm air ceanglaichean uèirichean airson teannachadh agus comharran caitheamh.

8. A ’dèanamh trioblaid

TrioblaidAdhbhar a dh’fhaodadh a bhith annFuasgladh
Tha an taisbeanadh bàn no dorcha.No power supply; faulty wiring; dead backup battery.Check power connections. Ensure 12V DC supply. Replace backup battery.
Chan eil prògraman a’ ruith.Timer is in manual ON/OFF mode; incorrect programming; current time not set.Set to AUTO ON/OFF mode using the MANUAL button. Verify program settings. Set current time correctly.
Programs are lost after power outage.Tha am bataraidh cùl-taic marbh no gun a bhith air a stàladh.Install or replace the 3V lithium backup battery.
Load does not turn ON/OFF.Incorrect wiring; faulty load; load exceeds current rating.Check load wiring. Test the load independently. Ensure load current is within 30A.

9. Barantas agus Taic

Airson fiosrachadh barantais no taic theicnigeach, thoir sùil air na sgrìobhainnean a chaidh a thoirt seachad aig àm ceannach no cuir fios chun neach-reic agad. Cùm do chuidhteas ceannach mar dhearbhadh ceannach.