1. Ro-ràdh

This manual provides comprehensive instructions for the proper use and maintenance of your TRUE METRIX® AIR Meter Starter Kit. This kit is designed for self-monitoring blood glucose levels and includes essential components for effective diabetes management.

TRUE METRIX AIR Meter Starter Kit components
Figear 1: Os a chionnview of the TRUE METRIX® AIR Meter Starter Kit.

The TRUE METRIX® AIR system utilizes advanced technology to provide accurate and reliable blood glucose readings, featuring Bluetooth Smart Connectivity for seamless data transfer to compatible mobile devices.

2. Dè tha air a ghabhail a-steach

Your TRUE METRIX® AIR Meter Starter Kit contains the following items:

  • TRUE METRIX® AIR Meter
  • 100 TRUE METRIX® Test Strips
  • 100 30g TRUEplus® Single-Use Sterile Lancets
  • TRUEdraw™ Lancing Device
  • TRUEplus® Log Book
  • METRIX® Control Solution (Level 1)
  • Cùis Giùlain Meatair
  • 1 CR2 battery (pre-installed)
Labeled components of the TRUE METRIX AIR Meter Starter Kit
Figear 2: Mionaideach view of the kit components, including the blood glucose monitor, compact carrying case, lancing device, self-test log book, level 1 control solution, test strips (100 count), and 30G lancets (100 count).

3. Suidhich

3.1. Stàladh bataraidh

The TRUE METRIX® AIR Meter comes with one CR2 battery pre-installed. If replacement is needed, ensure the meter is off, open the battery compartment, insert a new CR2 battery with the correct polarity, and close the compartment securely.

3.2. Setting Up the Lancing Device

  1. Unscrew caip an inneal lannachaidh.
  2. Insert a new sterile lancet firmly into the lancet holder.
  3. Twist off the protective cap from the lancet.
  4. Cuir caip an inneil-lannsaidh air ais.
  5. Adjust the penetration depth by rotating the cap. Start with a shallower setting and adjust as needed for a sufficient blood sample.
  6. Pull back the cocking barrel until it clicks, indicating it is ready for use.

3.3. Bluetooth Pairing with TRUE MANAGER™ AIR App

To wirelessly transfer your glucose results, pair your TRUE METRIX® AIR Meter with the TRUE MANAGER™ AIR app on your mobile device. Ensure Bluetooth is enabled on your mobile device and the meter is turned on.

  1. Download and open the TRUE MANAGER™ AIR app from your device's app store (available on iOS and Android).
  2. The first time you open the app, you will be prompted to agree to the End User License Agreement. Accept to proceed.
  3. A Bluetooth pairing request will appear on your mobile device screen.
  4. Locate the serial number (SN) on the back label of your TRUE METRIX® AIR Meter.
  5. Enter the last six digits of the meter's serial number into the PIN field on your mobile device. This is the meter's PIN number.
  6. Tap "OK" to confirm.
  7. Wait for your mobile device to confirm its connection to the meter. Once paired, the app can upload glucose results from the meter.
TRUE MANAGER AIR app device compatibility chart for iOS and Android
Figure 3: Device compatibility chart for the TRUE MANAGER™ AIR app, showing supported iOS and Android devices.

Video 1: "How to Pair, Manage and Sync to the TRUE Manager Air App" - This video demonstrates the process of pairing your TRUE METRIX® AIR meter with the TRUE MANAGER™ AIR app and syncing your blood glucose data.

4. Operating the TRUE METRIX® AIR Meter

4.1. A’ dèanamh deuchainn glùcois fala

  1. Wash your hands thoroughly with soap and warm water. Dry completely.
  2. Insert a new TRUE METRIX® Test Strip into the test strip port of the meter. The meter will turn on automatically.
  3. When the blood drop symbol flashes, indicating the meter is ready for a blood sample.
  4. Use the lancing device to obtain a blood sample from your fingertip.
  5. Dèan suathadh air bàrr na stiall deuchainn chun na fala sample. The blood will be drawn into the strip.
  6. The meter will display your blood glucose result in as fast as 4 seconds.
  7. Remove and discard the used test strip safely.
Hand holding TRUE METRIX AIR meter with test strip inserted, touching a blood sample on a fingertip
Figure 4: Proper technique for applying a blood sampris an stiall deuchainn.
Close-up of TRUE METRIX AIR meter displaying a blood glucose reading after a test
Figure 5: The meter displaying the blood glucose result.

4.2. tachartas Taga' fas

The TRUE METRIX® AIR meter allows for event tagging, which helps you categorize your blood glucose readings based on various events such as before meal, after meal, exercise, sick, medication, or other. This feature provides valuable insights into how different activities and conditions affect your glucose levels.

Video 2: "TRUE METRIX AIR Meter Glucose Monitor Starter Kit" - This video highlights the features of the TRUE METRIX® AIR meter, including event tagging capabilities.

4.3. Data Management and Syncing

The meter stores up to 1000 results with time/date stamps. Gu view and analyze your data, open the TRUE MANAGER™ AIR app on your paired mobile device. Press the sync button within the app to wirelessly transfer your new glucose results. The app provides various reports (Logbook, Averages, Conformance, Modal, Trend) to help you visualize and understand your blood glucose patterns.

5. Cumail suas

5.1. Glanadh a’ Mheatair

Regularly clean the exterior of your meter with a soft, damp cloth. Do not immerse the meter in water or use harsh cleaning agents. Ensure the test strip port is free of debris.

5.2. Stòradh

Store the TRUE METRIX® AIR Meter and test strips in a cool, dry place, away from direct sunlight and extreme temperatures. Keep all components in the provided carrying case when not in use to protect them from damage.

6. A ’dèanamh trioblaid

6.1. Bluetooth Connectivity Issues

  • Dèan cinnteach gu bheil Bluetooth air a chomasachadh air an inneal gluasadach agad.
  • Verify the meter is turned on and within range of your mobile device.
  • Re-enter the meter's PIN (last six digits of the serial number) during pairing if issues persist.
  • Restart both the meter and your mobile device.
  • Check the TRUE MANAGER™ AIR app for updates.

6.2. Leughaidhean mì-chruinn

  • Ensure test strips are not expired and are stored correctly.
  • Verify proper blood sample application technique.
  • Perform a control solution test to check meter and strip accuracy. Refer to the control solution instructions for details.
  • Ensure hands are clean and dry before testing.

For other error codes or persistent issues, refer to the detailed troubleshooting section in the full User Guide (PDF) available for download, or contact customer support.

7. Sònrachaidhean

FeartMion-fhiosrachadh
Ainm ModailAIRE
Sample MeudTiny 0.5 microliter
Ùine deuchainnCho luath ri 4 diogan
CuimhneStores 1000 results with time/date
CeangalachdBluetooth airson fòn 'smart'
Seòrsa bataraidh1 CR2 bataraidh (air a ghabhail a-steach)
DèanadairSlàinte Trividia
Àireamh Modail NìAir Meter Starter Kit

8. Barantas agus Taic

8.1. Àicheadh ​​Laghail

TRUE METRIX® AIR is intended for self-monitoring blood glucose only and not for multiple patient use. Only TRUE METRIX® PRO is intended for multiple patient use.

8.2. Taic teachdaiche

For any questions or concerns regarding your TRUE METRIX® AIR Meter Starter Kit or the TRUE MANAGER™ AIR app, please contact Customer Care:

Customer care representatives are available to personally assist you with any inquiries or help you connect your mobile device to your TRUE METRIX® AIR Self-Monitoring Blood Glucose Meter.

© 2024 TRUE METRIX. All rights reserved.

Sgrìobhainnean co-cheangailte - Air Meter Starter Kit

Ro-làimhview Stiallan Deuchainn Glùcois Fuil Fèin-sgrùdaidh TRUE METRIX Stiùireadh airson an Cleachdadh
Stiùireadh coileanta airson stiallan is meatairean deuchainn glùcois fala fèin-sgrùdaidh TRUE METRIX, TRUE METRIX AIR, agus TRUE METRIX GO a chleachdadh. A’ còmhdach an cleachdadh a tha san amharc, modhan deuchainn, smachd càileachd, fuasgladh dhuilgheadasan, crìochan, dàta coileanaidh, agus stiùiridhean sàbhailteachd airson riaghladh tinneas an t-siùcair.
Ro-làimhview TRUE METRIX Blood Glucose Test Strips: Instructions for Use, Safety, and Performance
Comprehensive guide for TRUE METRIX, TRUE METRIX AIR, and TRUE METRIX GO Self Monitoring Blood Glucose Test Strips. Includes intended use, testing procedures, quality control, troubleshooting, limitations, performance data, and an important update on E-5 error codes.
Ro-làimhview Leabhran Sealbhadair is Stiùireadh Deuchainn Luath airson Siostam Fèin-sgrùdaidh Glùcois Fuil TRUE METRIX
Leabhran oifigeil an t-sealbhadair agus stiùireadh deuchainn luath airson Siostam Fèin-sgrùdaidh Glùcois Fala TRUE METRIX le Trividia Health. Ionnsaich mar a nì thu deuchainn cheart air ìrean glùcois fala, mar a stiùireas tu an inneal agad, agus mar a lorgas tu taic.
Ro-làimhview TRUE METRIX GO Blood Glucose Monitoring System Quick Reference Guide
A quick reference guide for using the TRUE METRIX GO Self-Monitoring Blood Glucose System, including step-by-step instructions, tips, and safety information.
Ro-làimhview Meatair Glùcois Fuil TRUE METRIX PRO: Stiùireadh Luath-iomraidh
Stiùireadh luath airson a bhith a’ cleachdadh Mheatair Glùcois Fala TRUE METRIX PRO, le mion-fhiosrachadh air an stèidheachadh, modhan deuchainn, molaidhean cudromach, agus stiùireadh às dèidh làimhe airson sgrùdadh ceart air glùcois fala.
Ro-làimhview TRUE METRIX PRO Blood Glucose Test Strips: Instructions for Use & Performance
Comprehensive instructions for using TRUE METRIX PRO Blood Glucose Test Strips, covering intended use, test principles, chemical composition, safety precautions, proper handling, troubleshooting, limitations, and detailed performance characteristics for accurate blood glucose monitoring in professional healthcare settings.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.