1. Ro-ràdh
This manual provides important information regarding the installation, operation, and maintenance of your GBC iSnatch Carbon Monoxide (CO) Detector. Please read this manual thoroughly before using the device and retain it for future reference.
Carbon monoxide is a colorless, odorless, and tasteless gas that can be fatal. This detector is designed to monitor CO levels and alert you to potentially dangerous concentrations, helping to protect your household.
This CO detector complies with the EN50291-1 standard, ensuring its suitability for household use.
2. Fiosrachadh Sàbhailteachd agus Rabhaidhean
Cudromach: This device is designed to detect carbon monoxide gas. It is not designed to detect smoke, fire, or other gases. It is not a substitute for proper maintenance of fuel-burning appliances, including ventilation and exhaust systems.
- Do not paint the detector. Paint can clog the sensor openings and interfere with the detector's ability to detect CO.
- Do not block the ventilation openings on the detector.
- Test the detector regularly using the test button.
- Replace batteries promptly when the low battery warning is indicated.
- Do not install in areas with high humidity, extreme temperatures, or excessive dust.
- Cùm a-mach à ruigsinn chloinne.
3. Pasgan-susbaint
Dèan cinnteach gu bheil a h-uile nì anns a’ phacaid:
- GBC iSnatch Carbon Monoxide Detector (Model 64051105)
- Leabhar-làimhe cleachdaiche
4. Toradh thallview
The GBC iSnatch Carbon Monoxide Detector features a compact design with an integrated LCD display and indicator lights for easy monitoring.

Figear 1: Aghaidh view of the GBC iSnatch Carbon Monoxide Detector. It features a central digital display showing PPM (parts per million) of CO, a 'TEST' button, and three indicator lights at the bottom: 'POWER' (green), 'FAULT' (yellow), and 'ALARM' (red). Speaker grilles are visible on both sides of the display.
- Taisbeanadh LCD: Shows real-time CO concentration in PPM (Parts Per Million).
- Putan deuchainn: Used to verify the sensor and alarm functionality.
- Comharra Cumhachd (LED Uaine): Illuminates when the device is powered on and functioning correctly.
- Fault Indicator (Yellow LED): Illuminates to indicate a fault or low battery condition.
- Alarm Indicator (Red LED): Flashes when a CO alarm condition is detected.
- Sirean 85 dB: Emits a loud audible alarm during a CO event.
5. Setup agus Stàladh
5.1 Stàladh bataraidh
The detector operates on 1 x 9V battery (not included). Ensure the battery is installed correctly before use.
- Locate the battery compartment cover on the back of the detector.
- Fosgail an roinn bataraidh.
- Insert one 9V battery, observing the correct polarity (+/-).
- Dùin an còmhdach roinn bataraidh gu tèarainte.
- Upon successful battery installation, the detector will perform a self-test, and the green POWER LED should illuminate.
5.2 A’ taghadh àite stàlaidh
Airson an coileanadh agus an sàbhailteachd as fheàrr, smaoinich air na leanas nuair a thaghas tu àite:
- Install at least one CO detector on each level of your home, especially near sleeping areas.
- Place the detector at a height where it can be easily seen and heard, typically at eye level or higher.
- Avoid installing near fuel-burning appliances (furnaces, water heaters, stoves) to prevent nuisance alarms from normal operation.
- Do not install in direct sunlight, near windows or doors, or in areas with strong drafts, as this can affect sensor accuracy.
- Maintain a distance of at least 1.5 meters (5 feet) from any cooking or heating appliance.

Figear 2: Example installation of the CO detector on a wall in a kitchen area, demonstrating a suitable mounting height.
5.3 A’ cur suas an lorgaire
Once you have selected an appropriate location:
- Comharraich an suidheachadh stàlaidh a tha thu ag iarraidh air a’ bhalla.
- Drile dà tholl aig na h-àiteachan comharraichte.
- Cuir plugaichean balla (ma tha sin riatanach) a-steach do na tuill a chaidh a drileadh.
- Screw the mounting screws into the wall, leaving a small gap for the detector to hang.
- Align the mounting slots on the back of the detector with the screws and slide the detector down to secure it.
- Ensure the detector is firmly attached to the wall.
6. Stiùireadh Obrachaidh
6.1 Cumhachd Air adhart
After battery installation, the detector will automatically power on. The green POWER LED will light up, and the LCD display will show "0 PPM" or cycle through a brief startup sequence.
6.2 Obrachadh àbhaisteach
During normal operation, the green POWER LED will remain steadily lit, and the LCD display will show "0 PPM" if no CO is detected, or the current CO concentration if present.
6.3 Gnìomh deuchainn
It is recommended to test the detector weekly to ensure proper functionality.
- Press and hold the "TEST" button located on the front of the detector.
- The detector will emit a series of loud beeps (85 dB siren), and the red ALARM LED will flash. The LCD display may show a test value.
- Release the button. The detector should return to normal operation.
- If the detector does not respond as described, refer to the Troubleshooting section.
7. Alarm Conditions and Actions
The detector is designed to alarm at specific CO concentrations and durations as per EN50291-1:
- 50 pPM: Alarm within 60-90 minutes.
- 100 pPM: Alarm within 10-40 minutes.
- 300 pPM: Alarm within 3 minutes.
When a CO alarm occurs:
- The 85 dB siren will sound repeatedly.
- The red ALARM LED will flash rapidly.
- The LCD display will show the detected CO concentration in PPM.
What to do if the alarm sounds:
- Falmhaich sa bhad: Gluais a h-uile duine, nam measg peataichean, gu èadhar ùr a-muigh.
- Na cuir a-steach a-rithist: Do not re-enter the premises until the CO source has been identified and corrected, and the area has been thoroughly ventilated.
- Call Emergency Services: Contact your local emergency services or fire department.
- Comharraich an Stòr: After the area is safe, have a qualified technician inspect all fuel-burning appliances and chimneys for proper operation and ventilation.
8. Cumail suas
8.1 Regular Testing
Test the detector weekly by pressing the "TEST" button as described in Section 6.3.
8.2 Ath-nuadhachadh bataraidh
The detector will indicate a low battery condition by flashing the yellow FAULT LED and possibly emitting a chirp sound. Replace the 9V battery immediately when this occurs. Refer to Section 5.1 for battery installation instructions.
8.3 Glanadh
Clean the detector regularly to prevent dust buildup from affecting its performance.
- Cleachd bog, damp cloth to wipe the exterior of the detector.
- Do not use cleaning agents, solvents, or abrasive materials.
- Do not spray air fresheners, hairspray, or other aerosols near the detector.
- Gently vacuum around the sensor openings to remove dust.
9. A ’dèanamh trioblaid
| Trioblaid | Adhbhar a dh’fhaodadh a bhith ann | Fuasgladh |
|---|---|---|
| Chan eil an lorgaire a’ dol air. | Gun bataraidh no bataraidh air a stàladh gu ceàrr. | Install a fresh 9V battery, ensuring correct polarity. |
| Yellow FAULT LED flashes / Chirping sound. | Bataraidh ìosal. | Cuir am bataraidh 9V na àite sa bhad. |
| Alarm sounds without visible CO source. | False alarm due to interference or sensor issue. | Ventilate the area. If alarm persists, evacuate and contact emergency services. Ensure detector is not near sources of fumes or high humidity. |
| Test button does not activate alarm. | Faulty sensor or internal malfunction. | Ensure battery is fresh. If problem persists, the unit may need replacement. |
10. Sònrachaidhean
| Modail Àireamh | 64051105 |
| Brand | GBC |
| Seòrsa mothachaidh | Carbon monoxide electrochemical |
| Stòr cumhachd | Bataraidh 1 x 9V |
| Meud rabhaidh | 85 dB aig 1 meatair |
| Alarm Thresholds (PPM) | 50 PPM (60-90 min), 100 PPM (10-40 min), 300 PPM (within 3 min) |
| Taisbeanadh | LCD, real-time CO concentration |
| Meudan toraidh | 9.6 x 9.6 x 3.5 cm (3.78 x 3.78 x 1.38 òirleach) |
| Cuideam | 200 g (0.44 lbs) |
| Gèilleadh | EN50291-1 |
| Stuth | Plastaig |
11. Barantas agus Taic
Airson fiosrachadh barantais no taic theicnigeach, thoir sùil air na fiosrachadh conaltraidh a thug an neach-reic agad no oifigear an neach-dèanamh dhut. weblàrach. Cùm do chuidhteas ceannach mar dhearbhadh ceannach.
This product is designed for a specific lifespan. It is recommended to replace the CO detector after 7-10 years from the manufacturing date, or as indicated by the device's end-of-life signal, to ensure continued accuracy and reliability.