MAXSafes 10005NV

MAXSafes 10005NV Drawer Safe User Manual

Model: 10005NV

Ro-ràdh

The MAXSafes 10005NV Drawer Safe provides secure and quick access storage for your valuables and firearms. It features advanced finger vein recognition technology, a programmable electronic keypad, and a manual key override. Designed for discreet placement, this safe offers robust protection with its heavy-duty construction and convenient features like internal LED lighting and emergency power options.

MAXSafes 10005NV Drawer Safe with labeled features including heavy-duty housing, mechanical key entry, mounting bracket, LED light, backlit digital keypad, vein recognition scanner, built-in 9V battery box, and registration button.

Ìomhaigh: Tharview of MAXSafes 10005NV Drawer Safe with key features labeled.

Stàladh agus stàladh

Co-phàirtean air an toirt a-steach

  • 1 x MAXSafes 10005NV Biometric Safe
  • 1 x Leabhar-làimhe Cleachdaiche
  • 2 x Iuchraichean Sàrachaidh
  • Mounting Hardware (screws, mounting bracket)

Stàladh bataraidh

  1. Open the safe using the override key (see 'Manual Key Override' in Operation section).
  2. Locate the battery compartment inside the safe.
  3. Thoir air falbh an còmhdach bataraidh.
  4. Cuir bataraidh alcalin 9V ùr a-steach, a’ dèanamh cinnteach gu bheil e ceart ann am polarachd.
  5. Cuir an àite còmhdach bataraidh.

Mounting the Safe

The safe can be installed under a desk, inside a cabinet, or on a nightstand using the provided mounting bracket and hardware. Ensure the mounting surface is sturdy enough to support the safe's weight (approximately 14.3 lbs).

  1. Position the mounting bracket in your desired location.
  2. Mark the drilling points through the pre-drilled holes on the bracket.
  3. Dril tuill pìleat ma tha sin riatanach.
  4. Daingnich am bracaid sreap le bhith a’ cleachdadh nan sgriothan a tha air an toirt seachad.
  5. Slide the safe onto the mounted bracket until it locks securely into place.

Video: Instructions on how to install the MAXSafes drawer safe.

MAXSafes 10005NV Drawer Safe shown installed under a desk, on a flat surface, in a closet, and on a nightstand.

Image: Various installation options for the MAXSafes 10005NV Drawer Safe.

Obrachaidh

Fuasgladh an Sàbhailte

The MAXSafes 10005NV offers three methods for unlocking:

  • Finger Vein Recognition: Place a registered finger on the scanner. The safe will unlock in approximately 0.3 seconds.
  • Còd PIN: Enter your programmed 4-8 digit PIN code on the backlit digital keypad.
  • Sgaradh Iuchrach Làimhe: In case of battery failure or forgotten codes, use one of the provided override keys to manually open the safe. The keyhole is located on the side of the safe.

Video: Demonstration of how to use the MAXSafes drawer safe, including unlocking methods.

Three images showing the manual key, password keypad, and finger vein scanner for unlocking the MAXSafes 10005NV Drawer Safe.

Image: Three unlocking methods: Manual Key, Password Quick Access, and Finger Vein Recognition Quick Access.

Programming Finger Vein IDs

The safe can store up to 50 unique finger vein patterns.

  1. Fosgail an sàbhailte.
  2. Locate the program button inside the safe (under a rubber cover).
  3. Press the program button. The indicator lights will flash.
  4. Place the finger you wish to register on the finger vein scanner.
  5. Lift and place the same finger on the scanner two more times (total of three scans).
  6. The indicator lights will confirm successful registration.
  7. Repeat for additional finger vein IDs.

Prògramachadh còd PIN

Only one PIN code can be stored at a time. Programming a new code will overwrite the previous one.

  1. Fosgail an sàbhailte.
  2. Locate the program button inside the safe.
  3. Press the program button. The indicator lights will flash.
  4. Enter your desired 4-8 digit PIN code on the keypad.
  5. Press the program button again to confirm.
  6. Re-enter the same 4-8 digit PIN code to verify.
  7. The indicator lights will confirm successful programming.

Erasing All Finger Vein IDs

  1. Fosgail an sàbhailte.
  2. Locate the program button inside the safe.
  3. Press and hold the program button for 5 seconds.
  4. While still holding the program button, press the '4' key on the keypad.
  5. All registered finger vein IDs will be erased.

Modh Alarm

If three incorrect finger vein scans or PIN code entries are made consecutively, the safe's alarm will activate, and a 2-minute lockout period will begin. During this time, the safe cannot be opened using biometric or PIN methods. To end the lockout, enter a correct passcode, use a registered finger vein ID (if available), or remove and reinsert the 9V battery.

Cumail suas

Ath-nuadhachadh bataraidh

The safe requires one 9V alkaline battery. Replace the battery when the low battery indicator lights up or if the safe fails to respond. Always keep spare override keys in a secure location outside the safe.

Cumhachd Èiginn

In case the 9V battery is completely depleted, the safe features a Type-C emergency power outlet. Connect a Type-C cable to an external power source (e.g., power bank) to temporarily power the safe and gain access. This allows you to replace the internal 9V battery.

Close-up of the MAXSafes 10005NV Drawer Safe's battery compartment, showing a 9V battery being inserted.

Image: Battery compartment design for easy 9V battery replacement.

A hand plugging a Type-C cable into the emergency power outlet of the MAXSafes 10005NV Drawer Safe.

Image: Type-C emergency outlet for temporary power when the battery is low.

Glanadh

Sguab taobh a-muigh an t-seif le clò bog,amp cloth. Do not use abrasive cleaners or solvents. Keep the finger vein scanner clean and dry for optimal performance.

Fuasgladh thrioblaidean

  • Safe does not open with finger vein: Ensure your finger is clean and dry. Try repositioning your finger on the scanner. If multiple attempts fail, use the PIN code or manual key.
  • Chan eil an sàbhailte a’ fosgladh le còd PIN: Double-check the entered code. Ensure the keypad is responsive. If the alarm is active, wait for the lockout period to end or use the manual key.
  • No power/Safe unresponsive: Replace the 9V battery. If the battery is completely dead, use the Type-C emergency power outlet to temporarily power the safe and then replace the internal battery.
  • Alarm sounds frequently: Review recent access attempts. Ensure no unauthorized attempts are being made.

If you encounter persistent issues not covered here, please contact MAXSafes customer support for assistance.

Sònrachaidhean

BrandSàbhailteachd MAX
Modail Àireamh10005 NV
Meudan toraidh11.8"D x 10.63"W x 3.11"H
Seòrsa glasaidhBiometric (Finger Vein), Electronic Combination Lock, Key
DathDubh
StuthAlloy Steel
Feartan sònraichteAlarm System, Anti-Theft, Biometric Fingerprint, Internal LED Light, Type-C Emergency Power
Seòrsa stàladhFon Counter Mount
Cuideam nì14.33 Punnd
Bataraidhean a dhìth?Yes (1 x 9V Alkaline Battery)
UPC762736659784
Diagram showing the exterior and interior dimensions of the MAXSafes 10005NV Drawer Safe.

Image: Exterior and interior dimensions of the safe.

Barantas agus Taic

For warranty information or technical support, please refer to the contact details provided with your product packaging or visit the official MAXSafes weblàrach. Cùm do chuidhteas ceannach mar dhearbhadh ceannach airson tagraidhean barantais sam bith.