OLMO OW-P08HS115WF/ OW-TTWSLV
OLMO Through-the-Wall Air Conditioner & Heat System User Manual
Model: OW-P08HS115WF/ OW-TTWSLV
Ro-ràdh
Thank you for choosing the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System. This unit is designed to provide efficient heating and cooling for residential, commercial, or hotel use. It features a built-in wireless smart kit for convenient control via smartphone, an included remote control, and comes with a wall sleeve for installation.
This manual provides essential information for the safe and effective setup, operation, and maintenance of your OLMO unit. Please read it thoroughly before installation and use.
Figure 1: OLMO Through-the-Wall Air Conditioner and included accessories.
Stàladh agus stàladh
The OLMO Through-the-Wall Air Conditioner is designed for packaged installation. A wall sleeve is included with your unit to facilitate proper mounting.
Liosta sgrùdaidh ro-stàlaidh:
- Verify power supply: This unit requires a 115V, 1-phase, 60Hz power supply. Ensure you have the correct receptacle.
- Check dimensions: The product dimensions are approximately 20.28 x 24.21 x 14.53 inches. Ensure your wall opening is appropriately sized for the unit and wall sleeve.
- Confirm refrigerant: The unit is pre-charged with R-32 refrigerant.
Wall Sleeve Installation:
The included wall sleeve (Model: OW-TTWSLV) is crucial for secure and proper installation. Follow the detailed instructions provided in the separate installation guide for precise measurements and mounting procedures. Proper sealing and insulation around the sleeve are essential for optimal performance and energy efficiency.

Figure 2: Included Wall Sleeve (OW-TTWSLV).
Suidheachadh Aonaid:
Ensure the unit is installed in a location that allows for proper airflow around the intake and exhaust vents. Avoid placing objects directly in front of or on top of the unit that could obstruct air circulation.
Stiùireadh Obrachaidh
Your OLMO Through-the-Wall unit offers multiple control options for your convenience:
- Digital Push Button Control Panel: Located on the unit with an LED display for direct control.
- Included Remote Controller: Provides full functionality from a distance.
- Built-In Wireless Smart Kit: Allows control via a compatible smartphone application.
Feartan smachd aig astar:
The remote control allows you to adjust temperature, change modes (Cool, Heat, Fan, Dry, Auto), set fan speeds, and activate special features like Sleep Mode and Timer.

Figure 3: Remote Control for OLMO AC Unit.
Smart Connect (Wi-Fi) Operation:
The built-in Smart Connect feature enables you to control your unit remotely using a smartphone app. Download the official OLMO app from your device's app store and follow the in-app instructions to pair your unit. This allows for convenient control from anywhere with an internet connection.

Figure 4: Smartphone App for Smart Control.
Prìomh fheartan:
- Modh cadail: Bidh e ag atharrachadh an teòthachd gu fèin-ghluasadach airson cadal comhfhurtail agus sàbhaladh lùtha.
- Ath-thòiseachadh Auto: Tòisichidh an aonad ag ath-thòiseachadh gu fèin-ghluasadach leis na roghainnean roimhe às dèidh crìoch cumhachd.tage.
- Ioma astar luchd-leantainn: Tagh bho dhiofar astaran luchd-leantainn airson sruth-adhair gnàthaichte
- Uaireadair: Prògramaich an aonad gus a thionndadh air no dheth aig amannan sònraichte.
- Self-Evaporative System: Helps manage condensate, reducing the need for manual draining in most conditions.
- Taisbeanadh LED: Provides clear indication of settings and operating status.
- Fresh Air Input: Allows for introduction of fresh outdoor air.
Bhidio: Tharview of OLMO Through-the-Wall Air Conditioner features and capabilities. This video demonstrates the unit's design and highlights its smart connectivity and remote control options.
Cumail suas
Regular maintenance ensures optimal performance and longevity of your OLMO air conditioner. Always disconnect power to the unit before performing any maintenance.
Glanadh sìoltachan adhair:
The air filter should be cleaned every two weeks, or more frequently depending on usage and air quality. A dirty filter can reduce cooling/heating efficiency and airflow.
- Fosgail pannal aghaidh an aonaid.
- Carefully remove the air filter(s).
- Nigh an criathrag le uisge blàth, siabainneach. Sruthlaich gu mionaideach.
- Allow the filter to air dry completely before reinserting. Do not expose to direct sunlight or heat.
Glanadh coitcheann:
Sguab taobh a-muigh an aonaid le bog, damp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface. Ensure the drainage area is clear of debris.
Fuasgladh thrioblaidean
If you experience issues with your OLMO air conditioner, refer to the following common troubleshooting steps. For problems not listed here, or if issues persist, please contact OLMO customer support.
| Trioblaid | Adhbhar a dh’fhaodadh a bhith ann | Fuasgladh |
|---|---|---|
| Chan eil an aonad a’ tionndadh air | No power supply; Circuit breaker tripped; Unit unplugged. | Check power cord connection; Reset circuit breaker; Ensure unit is plugged into a functional 115V outlet. |
| Fuarachadh/teasachadh neo-iomchaidh | Dirty air filter; Obstructed airflow; Temperature setting too high/low; Room size exceeds capacity. | Clean air filter; Remove obstructions from vents; Adjust temperature setting; Ensure unit capacity matches room size. |
| Aonad fuaimneach | Pàirtean sgaoilte; Aonad gun a bhith rèidh; Bacadh air an neach-leantainn. | Check for loose components; Ensure unit is level; Inspect fan for obstructions. |
| Chan eil smachd iomallach ag obair | Bataraidhean marbh; Bacadh eadar an inneal iomallach agus an aonad. | Cuir bataraidhean ùra nan àite; Dèan cinnteach gu bheil loidhne-sheallaidh shoilleir gu glacadair an aonaid. |
Sònrachaidhean
Detailed technical specifications for the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System (Model: OW-P08HS115WF/ OW-TTWSLV).
| Sònrachadh | Luach |
|---|---|
| Ainm Brand | ELM |
| Fiosrachadh modail | OW-P08HS115WF/ OW-TTWSLV |
| Cuideam nì | 80 not |
| Meudan toraidh (D x W x H) | 20.28 x 24.21 x 14.53 òirleach |
| Dùthaich Tùs | Sìona |
| Èifeachdas | Math |
| Comas | 0.66 Tonna |
| Ìre fuaim | 52 dB |
| Seòrsa stàlaidh | Packaged, Through-the-Wall |
| Feartan sònraichte | Smachd iomallach, comas WiFi |
| Feartan teasachaidh | 1 |
| Dath | Geal |
| Voltage | 115 Volt |
| Co-phàirtean air an toirt a-steach | Through the Wall Air Conditioner, Wall Sleeve and Remote Control |
| Cumhachd fuarachaidh | 8000 Aonadan Teirmeach Bhreatainn |
| Reothadair | R-32 |

Figure 5: Comprehensive Technical Specifications Table.
Barantas agus Taic
For technical assistance, warranty inquiries, or further support, please contact OLMO customer service. Refer to your product packaging or the official OLMO weblàrach-lìn airson an fhiosrachadh conaltraidh as ùire.
You can also visit the official OLMO store for more product information and resources: OLMO Store on Amazon.