DOREMiDi MTC-20

DOREMiDi MTC-20 Timecode Sync Device User Manual

Model: MTC-20 | Brand: DOREMiDi

1. Ro-ràdh

The DOREMiDi MTC-20 LTC-MIDI Timecode Sync device is a versatile tool designed for synchronizing MIDI timecode and SMPTE LTC timecode. It integrates functions for timecode generation, timecode conversion, and timecode reading, making it an essential component for professional audio and video synchronization setups. The MTC-20 features standard USB MIDI, MIDI DIN, and LTC interfaces, enabling seamless timecode synchronization between computers, MIDI devices, and LTC devices. Its integrated OLED display provides real-time information on the current timecode status, ensuring precise control and monitoring.

2. Feartan toraidh

  • LTC MIDI Timecode Sync (MTC-20) synchronizes MIDI timecode and SMPTE LTC timecode.
  • Functions include timecode generation, timecode conversion, and timecode reading.
  • Equipped with standard USB MIDI interface, MIDI DIN interface, and LTC interface for broad compatibility.
  • Facilitates timecode synchronization between computers, MIDI devices, and LTC devices.
  • Features an OLED display screen to show current timecode information and working status.

3. Suidheachadh agus Ceanglaichean

Follow these steps to set up your DOREMiDi MTC-20 device:

  1. Solar cumhachd: Power the MTC-20 through the USB-B interface. Ensure a stable 5VDC power source. The power indicator will illuminate upon successful power connection.
    DOREMiDi MTC-20 device, top-down view, showing USB-B port, MIDI IN/OUT, and LTC IN/OUT ports.

    Ìomhaigh: Mullach view of the MTC-20 device, highlighting the USB-B port for power and data.

  2. Ceangail ris a’ choimpiutair: Connect the MTC-20 to your computer using a USB-B cable. This connection enables USB MIDI functionality and power.
    DOREMiDi MTC-20 device, side view, showing USB-B port and MIDI DIN ports.

    Ìomhaigh: Taobh view of the MTC-20, illustrating the USB-B and MIDI DIN ports for computer and MIDI device connections.

  3. Connect MIDI Devices: Use standard 5-Pin MIDI cables to connect the MIDI OUT of the MTC-20 to the MIDI IN of your MIDI device, and the MIDI IN of the MTC-20 to the MIDI OUT of your MIDI device.
    DOREMiDi MTC-20 with USB, MIDI, and LTC cables connected.

    Image: The MTC-20 with all necessary cables (USB, MIDI, LTC) connected, demonstrating a full setup.

  4. Connect LTC Devices: Use standard 3-Pin XLR cables to connect the LTC OUT of the MTC-20 to the LTC IN of your LTC device, and the LTC IN of the MTC-20 to the LTC OUT of your LTC device.
    DOREMiDi MTC-20 device, front view, showing LTC IN and LTC OUT XLR ports.

    Ìomhaigh: Aghaidh view of the MTC-20, highlighting the LTC IN and LTC OUT XLR ports for connecting LTC-compatible equipment.

  5. Com-pàirt thairisview: Refer to the diagram below for a labeled overview of the MTC-20's ports and controls.
    Diagram of DOREMiDi MTC-20 with numbered labels for each port and control.

    Image: A detailed diagram of the MTC-20, with numbered labels indicating the USB port (3), MIDI OUT (4), MIDI IN (5), OLED display (6), control knob (7), LTC IN (1), and LTC OUT (2).

4. Stiùireadh Obrachaidh

The MTC-20 features a single knob for navigation and parameter adjustment. Click the knob to select different setting items, and rotate the knob to change the parameters of the selected item.

4.1. Setting Timecode Input Source

The MTC-20 can operate as a timecode converter/reader or a timecode generator. Select the appropriate timecode input source based on your application:

  • Stòr USB: When MTC-20 is used as a timecode converter/reader, select "USB" if the timecode is input via the USB port. The device will output MIDI timecode via MIDI OUT and LTC timecode via LTC OUT.
    Diagram showing USB and MIDI timecode input sources and their outputs.

    Image: Flowchart illustrating timecode input from USB, with output to MIDI OUT and LTC OUT. Also shows MIDI IN as a source, outputting to USB, MIDI OUT, and LTC OUT.

  • MIDI Source: Select "MIDI" if the timecode is input via the MIDI IN port. The MTC-20 will then output MIDI timecode via USB and MIDI OUT, and LTC timecode via LTC OUT.
  • LTC Source: Select "LTC" if the timecode is input via the LTC IN port. The device will output MIDI timecode via USB and MIDI OUT, and LTC timecode via LTC OUT.
    Diagram showing LTC and GEN timecode input sources and their outputs.

    Image: Flowchart illustrating timecode input from LTC IN, with output to USB, MIDI OUT, and LTC OUT. Also shows GEN (internal generation) as a source, outputting to USB, MIDI OUT, and LTC OUT.

  • GEN (Generate) Source: To use the MTC-20 as a timecode generator, select "GEN". In this mode, the MTC-20 generates timecode internally, which is then output via MIDI OUT, USB, and LTC OUT. You can set the hours, minutes, and seconds, and choose the time frame format (24, 25, 30DF, 30).

Note: When the timecode input source is "USB/MIDI/LTC", the timecode is externally input, and therefore the timecode and time frame cannot be set directly on the device.

5. Cumail suas

To ensure the longevity and optimal performance of your DOREMiDi MTC-20, please observe the following maintenance guidelines:

  • Glanadh: Use a soft, dry cloth to clean the exterior of the device. Avoid using abrasive cleaners, solvents, or strong chemicals, as these can damage the finish and internal components.
  • Stòradh: Store the device in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. When not in use for extended periods, disconnect all cables.
  • Làimhseachadh: Handle the device with care. Avoid dropping it or subjecting it to strong impacts, which can damage the internal circuitry or external casing.
  • Fionnarachadh: Ensure proper ventilation around the device during operation to prevent overheating. Do not block any ventilation openings.

6. A ’dèanamh trioblaid

If you encounter issues with your MTC-20, please refer to the following common troubleshooting steps:

  • Gun chumhachd: If the power indicator does not light up, ensure the USB-B cable is securely connected to a 5VDC power source and the device. Try a different USB port or power adapter.
  • No Timecode Output/Input:
    • Verify all MIDI and LTC cables are correctly connected and are standard, functional cables.
    • Check the selected timecode input source on the MTC-20's OLED display. Ensure it matches your intended input (USB, MIDI, LTC, or GEN).
    • Confirm that the sending device is transmitting timecode correctly and the receiving device is configured to receive it.
  • Intermittent USB Connection (Windows PC): Some users have reported intermittent USB connection issues with Windows PCs. Ensure your MTC-20 firmware is up to date. Try connecting the device to a different USB port on your computer, or use a powered USB hub. Ensure your operating system's USB drivers are current.
  • Cùisean Taisbeanaidh: If the OLED display is blank or unreadable, ensure the device is powered on. If the issue persists, contact support.
  • Inneal nach eil air aithneachadh leis a’ choimpiutair: Reconnect the USB cable. Try a different USB port. Restart your computer. Check your computer's Device Manager (Windows) or System Information (macOS) to see if the device is listed. Install or update necessary drivers if prompted by your operating system.

If these steps do not resolve your issue, please contact DOREMiDi customer support for further assistance.

7. Sònrachaidhean

FeartLuach
Cuideam nì9.6 unnsa
Meud pacaid6.22 x 4.17 x 2.44 òirleach
ASINB0CSFGCYZV
Àireamh Modail NìMTC-20
Ceann-latha Ri fhaighinn an-toiseach16 Faoilleach, 2024
Innealan co-fhreagarrachMeur-chlàr
Bathar-bog le taicWindows, Mac, iOS, Android
Siostam-obrachaidhWindows, Mac, iOS, Android
BrandDOREMiDi
Teicneòlas ceangailUSB
Àireamh nan Sianalan1

8. Barantas agus Taic

For warranty information and technical support, please refer to the documentation included with your purchase or visit the official DOREMiDi website. DOREMiDi is committed to providing high-quality products and customer satisfaction. If you experience any issues or have questions regarding your MTC-20 device, please do not hesitate to contact their customer service team.

© 2024 DOREMiDi. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.