Jaycar QC1938

Leabhar-làimhe Cleachdaiche Oscilloscop Didseatach Jaycar Digitech QC1938 100MHz

1. Ro-ràdh

This manual provides detailed instructions for the safe and effective operation of your Jaycar Digitech QC1938 100MHz Digital Oscilloscope. Please read this manual thoroughly before using the device to ensure proper setup, operation, and maintenance. Retain this manual for future reference.

2. Fiosrachadh Sàbhailteachd

Observe the following safety precautions to prevent injury and avoid damage to the instrument or any products connected to it.

  • Stòr cumhachd: Connect the oscilloscope only to the power source specified in this manual.
  • Bun-stèidh: Ensure the instrument is properly grounded to prevent electric shock.
  • Sgrùdaidhean: Use only probes supplied or recommended by the manufacturer. Ensure probes are rated for the voltage air a thomhas.
  • Fionnarachadh: Do not block ventilation openings. Ensure adequate airflow around the instrument.
  • Àrainneachd: Operate the oscilloscope in a dry environment. Avoid exposure to moisture, dust, or extreme temperatures.
  • Seirbheis: Refer all servicing to qualified service personnel. Do not attempt to repair the instrument yourself.

3. Pasgan-susbaint

Dearbhaich gu bheil na nithean gu lèir a tha air an liostadh gu h-ìosal an làthair sa phacaid agad:

  • Jaycar Digitech QC1938 Digital Oscilloscope
  • 10:1 Passive Probe with 1.5m lead
  • 2 x BNC to Clip Test Leads
  • Càball USB
  • Stiùireadh cumhachd
  • Leabhar-làimhe cleachdaiche (an sgrìobhainn seo)

4. Toradh thallview

The Jaycar Digitech QC1938 is a 100MHz Digital Oscilloscope designed for precise electronic measurements. It features a 7-inch color LCD screen, two independent channels, and a built-in waveform generator.

Aghaidh view of the Digitech QC1938 Digital Oscilloscope displaying a sine wave on its screen.
Figear 4.1: Aghaidh view of the Digitech QC1938 Digital Oscilloscope. This image shows the main display, control knobs, function buttons, and input connectors for channels 1 and 2, along with the USB port.
Cearcallach view of the Digitech QC1938 Digital Oscilloscope, highlighting the side ventilation and handle.
Figear 4.2: Cearcallach view of the Digitech QC1938 Digital Oscilloscope. This perspective emphasizes the robust build, integrated handle for portability, and side ventilation grilles.
Cearcallach view of the Digitech QC1938 Digital Oscilloscope displaying a complex waveform.
Figear 4.3: Ceàrnach eile view of the Digitech QC1938 Digital Oscilloscope. The screen displays a different waveform, demonstrating the device's capability to visualize various signal types.

Prìomh fheartan:

  • 7-inch TFT color LCD screen with 800 x 480 pixel resolution
  • Two independent input channels
  • 100MHz bandwidth and 1GSa/s sampìre ling
  • 8M memory depth (single channel)
  • Integrated 25MHz waveform generator (Sine, Square, Ramp, Exponential, Noise, DC)
  • Auto scale function for automatic sine and square wave detection
  • 14 trigger modes including Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, and IIC
  • 5 serial protocol triggers and decodes: RS232/UART, I2C, SPI, CAN, and LIN
  • Two 3-digit digital voltmeters and a 6-digit hardware frequency indicator
  • 32 types of auto measurements with real-time statistics
  • USB Host/Device interface for computer control and data storage

5. Suidhich

5.1 Ceangal cumhachd

  1. Connect the supplied power lead to the power input on the rear panel of the oscilloscope.
  2. Plug the other end of the power lead into a grounded AC power outlet.
  3. Press the power button on the front panel to turn on the oscilloscope.

5.2 Ceangal Probe

  1. Connect the BNC connector of the passive probe to either Channel 1 (CH1) or Channel 2 (CH2) input on the front panel.
  2. Attach the ground clip of the probe to the circuit's ground point.
  3. Connect the probe tip to the test point in your circuit.
  4. Ensure the probe's attenuation setting (e.g., 1X or 10X) matches the setting on the oscilloscope for accurate readings.

6. Stiùireadh Obrachaidh

6.1 Gnìomh Bunaiteach

  • Auto Scale: Press the 'AUTO SET' button to automatically adjust vertical, horizontal, and trigger settings for a stable waveform display. This function detects sine and square waves automatically.
  • Vertical Controls (VOLTS/DIV, POSITION): Use the VOLTS/DIV knobs to adjust the vertical scale (voltage per division) for each channel. The POSITION knobs shift the waveform vertically.
  • Horizontal Controls (SEC/DIV, POSITION): Use the SEC/DIV knob to adjust the horizontal scale (time per division). The horizontal POSITION knob shifts the waveform horizontally.
  • Ìre brosnachaidh: Adjust the 'TRIGGER LEVEL' knob to set the voltage level at which the oscilloscope captures a waveform.

6.2 Gnìomhan Adhartach

  • Gineadair Waveform: Access the waveform generator menu to select and configure output waveforms such as Sine, Square, Ramp, Exponential, Noise, and DC. Connect the 'WAVE GEN' output to your circuit.
  • Modhan brosnachaidh: Utilize the 14 available trigger modes (Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC) to capture specific events. Select modes via the 'TRIGGER' menu.
  • Serial Protocol Decoding: The oscilloscope supports decoding for RS232/UART, I2C, SPI, CAN, and LIN protocols. Configure these settings in the 'DECODE' menu to view decoded data.
  • Tomhais: The device offers 32 types of automatic measurements with real-time statistics (maximum, minimum, standard deviation, etc.). Access these via the 'MEASURE' menu.
  • Ceangal USB: Connect a USB thumb drive to the USB Host port to save oscilloscope setups, waveforms, reference waveforms, CSV files, and images. The USB Device port allows for remote control from a computer using SCPI commands.

7. Cumail suas

7.1 Glanadh

To clean the instrument, use a soft cloth dampened with a mild detergent solution. Do not use abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is powered off and unplugged before cleaning.

7.2 Stòradh

When not in use, store the oscilloscope in a dry, dust-free environment away from direct sunlight and extreme temperatures. Use the original packaging or a suitable case for protection during transport.

8. A ’dèanamh trioblaid

If you encounter issues with your oscilloscope, refer to the following common problems and solutions:

TrioblaidAdhbhar a dh’fhaodadh a bhith annFuasgladh
Gun chumhachdPower cable not connected; Power outlet faulty; Power button not pressedCheck power cable connection; Test power outlet; Press power button firmly
Gun tonn-tonn air a thaisbeanadhProbe not connected; Incorrect input channel selected; Vertical/Horizontal scale incorrect; Trigger level too high/lowConnect probe to CH1/CH2; Select correct channel; Adjust VOLTS/DIV and SEC/DIV; Adjust TRIGGER LEVEL or use 'AUTO SET'
Tonn-chruth neo-sheasmhachIncorrect trigger settings; No stable trigger sourceAdjust trigger level; Select appropriate trigger mode; Ensure a stable signal source
Draibh USB gun aithneachadhUSB drive formatted incorrectly; Drive not fully insertedEnsure USB drive is FAT32 formatted; Re-insert USB drive firmly

Ma mhaireas an duilgheadas às dèidh dhut na fuasglaidhean seo fheuchainn, cuir fios gu taic luchd-cleachdaidh.

9. Sònrachaidhean

ParamadairSònrachadh
Taisbeanadh7 òirleach TFT Color LCD
Fuasgladh800x480 piogsail
Seòrsa TaisbeanaidhPoint, Vector
Sianalan2
Bandwidth100 MHz
SampÌre lingSuas ri 1 GSa/s
Doimhneachd Cuimhne8M (single channel)
Raon inghearach2mV / div ~ 10V / div
Fuasgladh inghearach8 pìos
Gineadair WaveformSine, Ceàrnag, Ramp, Exponential, Noise, DC
Eadar-aghaidhUSB Host, USB Device
Cuideam1.9 kg
Meudan (L x H x W)318mm x 150mm x 110mm

10. Barantas agus Taic

Airson fiosrachadh barantais agus taic theicnigeach, thoir sùil air na sgrìobhainnean a chaidh a thoirt seachad aig àm a’ cheannaich no cuir fios chun neach-reic agad. Cùm do dhearbhadh ceannach airson tagraidhean barantais.

© 2024 Jaycar. All rights reserved.