CHENXI CX-907

CHENXI CX-907 Chronograph Watch

Leabhar-làimhe Stiùireadh Cleachdaiche

Ro-ràdh

Thank you for choosing the CHENXI CX-907 Chronograph Watch. This timepiece combines classic design with modern functionality, featuring a precise quartz movement, chronograph capabilities, and a date display. To ensure optimal performance and longevity, please read this manual carefully before using your watch.

Pàirtean Uaireadair

Familiarize yourself with the main components of your CHENXI CX-907 watch:

  • Crùn: Air a chleachdadh airson an t-àm agus an ceann-latha a shuidheachadh.
  • Luchd-putaidh (A & B): Air a chleachdadh gus gnìomh a’ chronograph obrachadh.
  • Uair, Mionaid, Diogannan: For displaying the current time.
  • Chronograph Sub-dials: Tomhais an ùine a chaidh seachad.
  • Uinneag Ceann-latha: A ’taisbeanadh an ceann-latha làithreach.
  • Comharran soilleir: Provide visibility in low light conditions.
CHENXI CX-907 watch face with chronograph sub-dials and date window

Ìomhaigh: Aghaidh view of the CHENXI CX-907 watch, showing the main dial, sub-dials, hands, and crown.

Suidhich

1. A ’suidheachadh na h-ùine

  1. Tarraing an crùn a-mach gu suidheachadh 2 (an suidheachadh as fhaide a-muigh).
  2. Rotate the crown to move the hour and minute hands until the desired time is set. Ensure AM/PM is correctly observed if setting the date.
  3. Brùth an crùn air ais gu suidheachadh 0 (suidheachadh àbhaisteach) gus an uaireadair a thòiseachadh.

2. A’ suidheachadh a’ cheann-latha

  1. Tarraing an crùn a-mach gu suidheachadh 1 (a’ chiad chlic).
  2. Tionndaidh an crùn deiseal no tuathal (a rèir a’ ghluasaid) gus an ceann-latha ceart a shuidheachadh.
  3. Cho luath ‘s a bhios an ceann-latha air a shuidheachadh, brùth an crùn air ais gu suidheachadh 0.
  4. Note: Avoid setting the date between 9 PM and 3 AM, as this can interfere with the automatic date change mechanism. If the date needs adjustment during this period, first set the time outside this range, adjust the date, then reset the time.

3. A’ gleusadh a’ bhràisleid

The watch features a 316 solid steel strap with a butterfly double snap buckle. For proper fit, links may need to be added or removed by a qualified watch technician.

CHENXI CX-907 watch with butterfly double snap buckle

Image: Close-up of the watch's butterfly double snap buckle and solid steel strap.

Ag obair an Chronograph

The chronograph function allows you to measure elapsed time independently of the main time display.

  1. Tòisich: Press pusher A (top pusher) to start the chronograph. The chronograph second hand and sub-dials will begin to move.
  2. Stad: Press pusher A again to stop the chronograph. The elapsed time will be displayed on the sub-dials.
  3. Ath-shuidhich: Às dèidh dhut an chronagraf a stad, brùth air putan B (putan aig a’ bhonn) gus na làmhan chronagraf uile ath-shuidheachadh gu na suidheachaidhean neoni aca.
  4. Intermediate Time (Split Time): Some chronographs allow for split time measurement. If your model supports this, press pusher B during measurement to temporarily stop the display while the timing continues internally. Press B again to catch up. Consult a watch specialist if unsure.

Cumail suas

1. Seasmhachd Uisge (30M)

Your CHENXI CX-907 watch is water-resistant to 30 meters (3 ATM). This rating means it is suitable for daily use and can withstand splashes or brief immersion in water. It is not suitable for swimming, showering, diving, or any activities involving prolonged water exposure or high-pressure water. Dèan cinnteach an-còmhnaidh gu bheil an crùn air a phutadh a-steach gu tur gus a chumail an aghaidh uisge.

2. Glanadh

Wipe the watch case and bracelet regularly with a soft, dry cloth to remove dust and dirt. For stubborn grime, a slightly damp Faodar clò a chleachdadh, agus an uair sin tiormaich sa bhad e. Seachain innealan-glanaidh ceimigeach no stuthan sgrìobach a chleachdadh.

3. Ath-nuadhachadh bataraidh

The watch is powered by a quartz movement (PE90). When the battery runs low, the watch may stop or the second hand may jump in irregular intervals. Battery replacement should be performed by a qualified watch technician to ensure proper sealing and maintain water resistance.

Back of CHENXI CX-907 watch showing stainless steel back and water resistance marking

Ìomhaigh: Cùl view of the CHENXI CX-907 watch, displaying the stainless steel back with brand and water resistance details.

Fuasgladh thrioblaidean

  • Uaireadair gun a bhith a’ ruith:

    Check if the crown is fully pushed in. If it is, the battery may need replacement. Consult a watch technician.

  • Ùine/Ceann-latha ceàrr:

    Refer to the "Setting the Time" and "Setting the Date" sections. Ensure the crown is fully pushed in after adjustment.

  • Làmhan a’ Chronograph gun ath-shuidheachadh gu neoni:

    This may indicate a need for calibration or service. Avoid forcing the pushers. A watch technician can usually recalibrate the chronograph hands.

  • Dlùthadh taobh a-staigh a’ chriostail:

    This indicates a loss of water resistance. Avoid further contact with water and seek immediate professional service to prevent damage to the movement.

Sònrachaidhean

BrandCHENXI (QTMIAO)
Modail ÀireamhCX-907
Seòrsa gluasadQuartz (PE90)
Seòrsa TaisbeanaidhAnalog (Multi-needle)
Frith-aghaidh uisge30 Meters (3 ATM) - Daily life waterproof
Trast-thomhas na cùise43 mm
Meud cùise10.5 mm
Stuth cùiseAlloy
Stuth SgàthanMineral Reinforced Glass
Stuth strap316 Solid Steel
Fad strap190 mm
Leud strap22 mm
Seòrsa claspButterfly Double Snap Buckle
FeartanLuminous, Chronograph, Calendar
Cuideam toraidh200 g

Barantas agus Taic

This product comes with a shop guarantee. For any issues, repairs, or further assistance, please contact the retailer or authorized service center where you purchased the watch. Always retain your proof of purchase for warranty claims.

For general inquiries or technical support, refer to the contact information provided by your seller.

© 2023 CHENXI. All rights reserved.