Ro-ràdh
This manual provides comprehensive instructions for the safe and efficient operation, setup, and maintenance of your Pulsar PG10000B16 10,000W Dual Fuel Portable Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
Prìomh fheartan:
- 10,000W peak / 8,000W rated (gasoline) and 9,000W peak / 7,000W rated (LPG) power output.
- Equipped with a powerful 420cc, 4-stroke, OHV, air-cooled engine.
- Features a large 6.6-gallon fuel tank, providing up to 12 hours of continuous operation at half load on gasoline.
- Includes Switch & Go technology for seamless transitioning between LPG and gasoline fuel sources during operation.
- Electric push start with recoil backup for quick and easy startup.

Figear 1: Os a chionnview of the Pulsar PG10000B16 Dual Fuel Portable Generator.
Suidheachadh agus Seanadh
Before operating your generator, ensure it is properly assembled and prepared for use. This section outlines the initial setup steps.
1. Unpacking agus Sgrùdadh:
- Thoir an gineadair a-mach às a phacaid gu faiceallach.
- Inspect for any shipping damage. Contact your retailer immediately if damage is found.
- Dèan cinnteach gu bheil na pàirtean uile a tha air an liostadh air an liosta pacaidh an làthair.
2. Wheel and Handle Assembly:
Attach the wheels and drop-down handles to the generator frame. This process may be easier with two people due to the unit's weight. Ensure all fasteners are securely tightened.

Figure 2: The generator with its wheels and handles attached, ready for transport.
3. A 'cur ola einnsean:
- Lorg caip lìonaidh/dipstick na h-ola.
- Add the recommended engine oil (refer to the oil type and capacity in the Specifications section) until it reaches the full mark on the dipstick. Do not overfill.
4. Fuel Connection:
- Gasoline: Lìon an tanca connaidh le peatrail ùr, gun luaidhe. Na lìon cus dheth.
- LPG: Connect an LPG tank to the generator's LPG connection point using a suitable hose and regulator. Ensure all connections are secure and leak-free.

Figure 3: The control panel showing the fuel switch and various outlets.
5. Ceangal Bataraidh:
Connect the battery cables to the battery terminals, ensuring correct polarity (red to positive, black to negative). The generator features an electric start, powered by this battery.
Stiùireadh Obrachaidh
Follow these steps for safe and effective operation of your Pulsar Dual Fuel Generator.
1. A 'tòiseachadh an Generator:
- Taghadh connaidh: Use the "Switch & Go" lever on the control panel to select either Gasoline or propane (LPG).
- Luamhan Tadhail: If starting a cold engine, move the choke lever to the "Closed" position. For a warm engine, leave it "Open".
- Switch einnsean: Tionndaidh suidse an einnsein chun t-suidheachaidh "ON".
- Tòisich dealain: Brùth agus cum sìos am putan tòiseachaidh dealain gus an tòisich an t-einnsean.
- Recoil Start (Backup): If the electric start fails or the battery is low, pull the recoil start handle firmly and smoothly until the engine starts.
- Once the engine starts, gradually move the choke lever to the "Open" position.
2. "Switch & Go" Dual Fuel Technology:
The generator's "Switch & Go" feature allows you to seamlessly switch between gasoline and LPG fuel sources even while the generator is running. To switch fuels, simply move the fuel selector lever to the desired fuel type. This can be done without shutting down the generator, providing flexibility during extended power outagtha.
3. Connecting Electrical Devices:
The generator provides multiple AC outlets (120V and 120V/240V) and a DC 12V 8.3A output for battery charging. Always ensure the total wattage of connected devices does not exceed the generator's rated running wattage.
- For sensitive electronics, it is recommended to use a quality surge protector or inverter-style power strip to protect against power fluctuations.
- Ensure all devices are turned off before plugging them into the generator.
- Never overload the generator.

Figure 4: The control panel displaying the engine switch, hour meter, DC 12V 8.3A output, and multiple AC 120V and AC 120V/240V outlets.
4. Shutting Down an Generator:
- Dì-cheangail a h-uile luchd dealain bhon ghineadair.
- Leig leis an gineadair ruith airson beagan mhionaidean gun luchd gus am fuaraich e.
- Tionndaidh suidse an einnsein dhan t-suidheachadh "OFF".
- If storing for an extended period, turn off the fuel valve (for gasoline) or close the LPG tank valve.
Cumail suas
Regular maintenance is crucial for the longevity and reliable performance of your generator. Always ensure the generator is turned off and cooled down before performing any maintenance.
1. Engine Oil:
- Thoir sùil air ìre na h-ola ro gach cleachdadh.
- Change oil after the first 20 hours of operation, then every 100 hours or annually, whichever comes first.
2. Air Filter:
- Inspect the air filter every 50 hours or monthly.
- Clean or replace if dirty.
3. Pluga lasachaidh:
- Inspect and clean the spark plug every 100 hours or annually.
- Cuir fear eile na àite ma tha e caite no millte.
4. Fuel System:
- For gasoline, use a fuel stabilizer if storing for more than 30 days.
- Drain the carburetor and fuel tank if storing for longer periods without stabilizer.
- For LPG, ensure the tank and connections are free from leaks.
5. Stòradh:
- Store the generator in a clean, dry, and well-ventilated area.
- Cover the generator to protect it from dust and moisture.
Fuasgladh thrioblaidean
This section provides solutions to common operational issues. If you encounter problems not listed here, or if the suggested solutions do not resolve the issue, contact customer support.
Generator Will Not Start:
- Gun chonnadh: Check gasoline level or LPG tank connection and supply.
- Comhla connaidh: Ensure the fuel valve is in the "ON" position.
- A' tachdadh: Atharraich luamhan an t-slocaidh mar a bhios iomchaidh airson einnsean fuar no blàth.
- Switch einnsean: Verify the engine switch is in the "ON" position.
- Plug Spark: Thoir sùil air a’ phluga lasachaidh airson salachar no milleadh.
- Bataraidh (Tòiseachadh Dealain): Check battery charge. If low, use the recoil start.
Gun toradh cumhachd:
- Luchd-brisidh Circuits: Check if any circuit breakers on the control panel have tripped. Reset if necessary.
- Overload: Reduce the total load connected to the generator.
- Ceanglaichean: Dèan cinnteach gu bheil na càbaill cumhachd uile air an plugadh gu tèarainte a-steach do shocaidean an gineadair.
An t-inneal a’ ruith gu dona:
- Connadh Seann: Use fresh fuel. Drain old fuel if necessary.
- Filter Adhair: Clean or replace a dirty air filter.
- Plug Spark: Dèan sgrùdadh agus glan no cuir fear eile na àite am pluga lasachaidh.
Sònrachaidhean
| Feart | Mion-fhiosrachadh |
|---|---|
| Brand | Pulsar |
| Ainm Modail | Portable Dual Fuel Generator- 8000 Rated Watts & 10000 Peak Watts - Gas & LPG |
| Àireamh Modail Nì | PG10000B16 |
| Dètage (Buaic) | 10,000 Watts (Gasoline) / 9,000 Watts (LPG) |
| Dètage (A’ ruith) | 8,000 Watts (Gasoline) / 7,000 Watts (LPG) |
| Seòrsa connaidh | Gasoline, Liquefied Petroleum Gas (LPG) |
| Seòrsa einnsean | 4-Stroke, OHV, Air Cooled |
| Gluasad einnsean | 420 Ceudameatair Ciùbach |
| Meud tanca connaidh | 6.6 Gall |
| Seòrsa Siostam Lasachaidh | Electric Start with Recoil Backup |
| Voltage | 120V / 240V AC, 12V DC |
| Innealan cumhachd iomlan | 6 |
| Cuideam nì | 209 Punnd |
| Meudan toraidh | 28.5"F x 21.8"L x 22.2"À |
| Stuth | Stàilinn |
| Feart sònraichte | Dual Fuel, Switch & Go Technology |

Figure 5: Product dimensions of the Pulsar PG10000B16 generator.
Barantas agus Taic
For detailed warranty information, please refer to the warranty card included with your product or visit the official Pulsar website. If you require technical assistance, replacement parts, or have questions regarding your generator, please contact Pulsar customer support.
Fiosrachadh conaltraidh: Refer to your product packaging or the official Pulsar weblàrach airson fiosrachadh conaltraidh taic luchd-cleachdaidh as ùire.