1. Ro-ràdh
This manual provides essential information for the installation, operation, and maintenance of your Hansa Bath Thermostat, model 58102101. This thermostat is designed for wall-mount applications and features integrated scalding protection for user safety. Please read these instructions carefully before installation and use to ensure proper function and longevity of the product.

Figure 1: Hansa Bath Thermostat 58102101, Chrome finish.
2. Fiosrachadh Sàbhailteachd
RABHADH: Dh’fhaodadh fàilligeadh ann a bhith a’ leantainn nan stiùiridhean sàbhailteachd seo dochann no milleadh a dhèanamh air an toradh.
- Scalding Protection: This thermostat is equipped with a safety stop at approximately 38°C (100.4°F) to prevent accidental scalding. This feature can be overridden for higher temperatures by pressing a button, but exercise extreme caution.
- Stàladh proifeiseanta: Installation should be performed by a qualified professional in accordance with local plumbing and building codes.
- Brùthadh uisge: Ensure water pressure is within the recommended range for optimal performance and to prevent damage.
- Glanadh: Use only mild cleaning agents. Abrasive cleaners can damage the chrome finish.
- Backflow Prevention: The unit includes backflow preventers in the S-connections, making it safe against backflow in domestic use (as per DIN EN 1717).
3. Pasgan-susbaint
Dèan cinnteach gu bheil na pàirtean uile an làthair mus tòisich thu air an stàladh:
- Hansa Bath Thermostat unit (Model 58102101)
- S-connections with dirt collection filters and backflow preventers
- Bathar-cruaidh stàlaidh (sgriuban, plugaichean balla)
- Leabhar-stiùiridh (an sgrìobhainn seo)
4. Setup agus Stàladh
4.1 Sgrùdaidhean ro-stàlaidh
- Cuir dheth am prìomh sholar uisge mus tòisich thu air obair sam bith.
- Ensure the wall surface is clean, dry, and structurally sound to support the thermostat.
- Verify that the hot and cold water supply lines are correctly identified.
4.2 A’ cur suas an teirmeastat
- Mark the drilling points for the S-connections on the wall. The standard center distance for connections is 150 +/- 15 mm.
- Dril tuill agus cuir a-steach plugaichean balla.
- Attach the S-connections to the wall, ensuring the dirt collection filters and backflow preventers are correctly oriented.
- Connect the hot and cold water supply lines to the respective S-connections. Hot water is typically on the left, cold on the right.
- Mount the thermostat body onto the S-connections and tighten securely.

Figure 2: Technical drawing showing key dimensions. Overall depth is 182mm. Connection size is G 1/2.
4.3 Às dèidh an Stàlaidh
- Tionndaidh gu mall air a 'phrìomh sholar uisge.
- Thoir sùil air a h-uile ceangal airson aoidion.
- Test the thermostat's function, including temperature control and diverter.
5. Stiùireadh Obrachaidh
5.1 Smachd Teòthachd
The thermostat features a single operating handle. Rotate the handle to adjust the water temperature. The safety stop is set at approximately 38°C (100.4°F). To exceed this temperature, press the safety button on the handle while rotating it further.
5.2 Flow Control and Diverter
The same operating handle also controls the water flow. Push or pull the handle to turn the water on or off and adjust the flow rate. The integrated diverter allows you to switch between the bath spout and a connected shower head. The flow rate is approximately 22 L/min for the spout and 19 L/min for the shower head, measured at 3 bar dynamic pressure.
6. Cumail suas
6.1 Glanadh
To maintain the chrome finish, clean the thermostat regularly with a soft cloth and a mild, non-abrasive cleaning agent. Avoid using harsh chemicals, abrasive sponges, or acidic cleaners, as these can damage the surface.
6.2 Dirt Collection Filters
The S-connections contain dirt collection filters to protect the thermostat from impurities in the water supply. If you notice a decrease in water flow or inconsistent temperature, these filters may need cleaning. Turn off the water supply, carefully remove the S-connections, clean the filters under running water, and reassemble.
6.3 Thermal Disinfection
The thermostat is suitable for thermal disinfection according to W551 DVGW-tested standards, provided the temperature lock is not mounted. Consult a professional for specific procedures if thermal disinfection is required.
7. A ’dèanamh trioblaid
- No Water Flow or Low Flow: Check if the main water supply is on. Inspect the dirt collection filters for blockages (refer to Section 6.2).
- Teòthachd neo-chunbhalach: Ensure hot and cold water supplies are correctly connected. Clean dirt collection filters. If the issue persists, the thermostat cartridge may require professional inspection or replacement.
- Aodion aig Ceanglaichean: Tighten connections carefully. If leaks persist, check the condition of seals and O-rings. Do not overtighten.
- Safety Stop Engaged (38°C): This is a normal safety feature. To exceed 38°C, press the safety button on the handle while rotating.
For issues not listed here, or if troubleshooting steps do not resolve the problem, please contact a qualified plumber or Hansa customer support.
8. Sònrachaidhean
| Feart | Mion-fhiosrachadh |
|---|---|
| Brand | Hansa |
| Modail Àireamh | 58102101 |
| Seòrsa Crìochnachaidh | Chrome |
| Seòrsa stàladh | Srath balla |
| Àireamh de làmhan | 1 |
| Co-phàirtean air an toirt a-steach | Teirmeastat |
| Seòrsa stàlaidh | Farsaing |
| Cuideam nì | 5.79 not |
| Meudan toraidh | 14.49 x 7.72 x 3.46 òirleach |
| Meud Ceangal | G 1/2 |
| Center Distance Connections | 150 +/- 15 mm |
| Flow Rate (Spout/Shower) | 22 L/min / 19 L/min (at 3 bar) |
| Scalding Protection | Safety stop at approx. 38°C |
9. Barantas agus Taic
Hansa products are manufactured to high-quality standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Hansa weblàrach.
For technical support, spare parts, or service inquiries, please contact your local Hansa dealer or visit the Hansa Store on Amazon.