Ro-ràdh
The Vanco SS6 is a low-profile speaker selector unit designed to distribute high-level (amplified) stereo signals to up to six independent zones. It features a manually activated impedance protection circuit to safeguard your receiver and maintain optimal sound quality across all connected speakers. This manual provides essential information for proper installation, operation, and maintenance of your SS6 unit.
Fiosrachadh Sàbhailteachd Cudromach
- Leugh a h-uile stiùireadh gu faiceallach mus obraich thu an inneal.
- Na cuir an aonad seo fo uisge no taiseachd.
- Ensure all connections are secure before powering on your audio system.
- Always disconnect power before making or changing any connections.
- Na feuch ri seirbheis a thoirt don aonad seo thu fhèin. Thoir aire do luchd-obrach teisteanasach airson a h-uile seirbheis.
Susbaint pacaid
Dèan cinnteach gu bheil na nithean a leanas anns a’ phacaid agad:
- Vanco SS6 6-Pair Stereo Speaker Selector Box
- Leabhar-stiùiridh (an sgrìobhainn seo)
Bathar seachadview

Figear 1: Aghaidh view of the Vanco SS6 6-Pair Stereo Speaker Selector Box. This image shows the compact design and the individual speaker zone selection buttons.

Figear 2: Cùl view of the Vanco SS6 showing the push terminal connections for amplifier input and six speaker zone outputs. Note the impedance protection switch.
The Vanco SS6 allows you to connect a single stereo amplifier to up to six pairs of speakers, enabling audio distribution to different rooms or zones. Each zone can be independently turned on or off. The unit incorporates an impedance protection circuit to prevent your amplifier from operating below a safe impedance level, which can be manually activated or deactivated depending on your system's configuration and the use of impedance-matching volume controls.
Stàladh agus stàladh
Follow these steps to properly set up your Vanco SS6 speaker selector box:
- Cumhachd dheth: Dèan cinnteach gu bheil do amplifier and all audio components are powered off and unplugged from the main power supply before making any connections.
- Speaker Wire Preparation: Prepare your speaker wires (14 to 22 AWG recommended) by stripping approximately 1/4 inch (6mm) of insulation from the ends. Twist the bare wire strands tightly.
- Ceangail Amplosgadair: Connect the speaker output terminals of your stereo ampneach-tabhairt don "AMPLIFIER INPUT" push terminals on the rear of the SS6 unit. Ensure correct polarity (+ to + and - to -).
- Ceangail Luchd-labhairt: Connect each pair of speakers to the corresponding "SPEAKER ZONE" push terminals (1 through 6) on the rear of the SS6 unit. Maintain correct polarity for each speaker pair.
- Impedance Protection:
- Activate (Recommended): For most setups, especially when connecting multiple speaker pairs to a single amplifier without impedance-matching volume controls, activate the impedance protection circuit. This prevents the amplifier's impedance from dropping below 5 ohms, protecting your receiver.
- Cuir dheth: If you are using impedance-matching volume controls in each zone or have a specific system design that accounts for impedance, you may deactivate the protection circuit. Consult an audio professional if unsure.
- Suidheachadh: Place the SS6 unit in a well-ventilated area, away from heat sources and direct sunlight. Its low-profile design allows for flexible placement.
- Cumhachd air: Once all connections are secure and verified, plug in and power on your amplifier and other audio components.
Stiùireadh Obrachaidh
Using your Vanco SS6 is straightforward:
- Select Zones: Press the corresponding button on the front panel for each speaker zone you wish to activate. The button will typically illuminate or indicate its active status.
- Deselect Zones: Press the button again to deactivate a speaker zone.
- Smachd tomhas-lìonaidh: Atharraich an tomhas-lìonaidh le bhith a’ cleachdadh do amplifier's volume control. If using impedance-matching volume controls in individual zones, adjust those as needed.
- Impedance Protection: If the impedance protection circuit is activated, it will automatically prevent the amplifier from seeing an impedance below 5 ohms, regardless of how many speaker pairs are active or their individual impedance ratings.
Cumail suas
The Vanco SS6 requires minimal maintenance. Keep the unit clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents. Ensure adequate ventilation around the unit to prevent overheating.
Fuasgladh thrioblaidean
- Gun fhuaim:
- Check all speaker wire connections for proper seating and polarity.
- Dèan cinnteach gu bheil an amplifier is powered on and playing audio.
- Verify that the desired speaker zones are selected on the SS6 unit.
- Check the volume levels on both the amplifier and any in-zone volume controls.
- Fuaim air a shaobhadh:
- Dèan cinnteach nach eil uèirichean an luchd-labhairt air an sgoltadh no air an giorrachadh.
- Check that the impedance protection is correctly set for your system.
- Lùghdaich amplifier volume to see if distortion persists.
- Cus teasachadh an aonaid:
- Ensure adequate ventilation around the SS6 unit.
- Verify that the impedance protection is activated if you are running multiple low-impedance speakers.
Sònrachaidhean
| Modail Àireamh | SS6 |
| Meudan toraidh | 6.5 x 17 x 2.5 òirleach |
| Cuideam nì | 2.85 not |
| Cumhachd Rangaichte | 100 Watts continuous per channel |
| Raon Impedance | 4 gu 16 Ohm |
| Slat-tomhais uèir neach-labhairt | 14 gu 22 AWG |
| Àireamh de phuirt | 6 (càraidean) |
| Dath | Dubh |
Barantas agus Taic
For warranty information or technical support, please refer to the Vanco official weblàrach-lìn no cuir fios chun roinn seirbheis teachdaiche aca. Cùm do chuidhteas ceannach mar dhearbhadh ceannach airson tagraidhean barantais sam bith.