StarTech.com RKPW081915

StarTech.com 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (RKPW081915) Instruction Manual

Model: RKPW081915

1. Ro-ràdh

This manual provides instructions for the installation, operation, and maintenance of your StarTech.com 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (Model RKPW081915). This Power Distribution Unit (PDU) is designed to provide reliable power distribution and surge protection for equipment within network server racks and cabinets.

2. Fiosrachadh Sàbhailteachd

RABHADH: Dh’fhaodadh fàilligeadh ann a bhith a’ leantainn nan stiùiridhean sàbhailteachd seo teine, clisgeadh dealain no leòn no milleadh eile adhbhrachadh.

  • Leugh a h-uile stiùireadh mus obraich thu an toradh.
  • Tha an toradh seo airson a chleachdadh a-staigh a-mhàin.
  • Ensure the PDU is properly grounded. Do not use with ungrounded outlets.
  • Do not exceed the maximum electrical rating of 120V/15A. Overloading the PDU can cause damage and fire hazards.
  • Do not disassemble or modify the PDU. Refer all servicing to qualified personnel.
  • Cùm air falbh bho uisge no cus taiseachd.
  • Do not plug one PDU into another.

3. Pasgan-susbaint

StarTech.com RKPW081915 PDU and Instruction Manual in packaging

Image: The StarTech.com PDU and its instruction manual, as typically found in the product packaging.

  • 1x 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (RKPW081915)
  • 1 x Leabhar-làimhe Stiùiridh

4. Toradh thallview

The StarTech.com RKPW081915 is a 1U horizontal rack-mountable PDU designed for efficient power distribution in server environments. It features 8 NEMA 5-15R outlets, a 6-foot power cord, and built-in surge protection.

Feartan pannal aghaidh

Aghaidh agus cùl view of the StarTech.com RKPW081915 PDU with labeled components

Ìomhaigh: Mion-fhiosrachadh view of the PDU's front and back, highlighting the LED indicators, power switch, and outlets.

  • LED Surge Indicator: Illuminates when surge protection is active.
  • LED Ground Indicator: Illuminates when the PDU is properly grounded.
  • Power/Reset Switch: Controls power to all outlets and acts as a circuit breaker reset.

Feartan pannal cùil

  • 8 x NEMA 5-15R Outlets: Provides power connections for your equipment.
  • Integrated 6ft Power Cord: Connects the PDU to a power source.
Cùl view of the StarTech.com RKPW081915 PDU showing the 8 NEMA 5-15R outlets and power cord

Image: Close-up of the rear of the PDU, displaying the eight power outlets and the attached power cord.

5. Suidhich

5.1 A’ dì-phapadh

Carefully remove the PDU and all components from the packaging. Inspect for any damage during shipping. If any damage is found, contact your vendor immediately.

5.2 Stàladh raca

The RKPW081915 PDU is designed for horizontal mounting in any standard 19-inch server rack that is 4 inches (10.16 cm) deep or greater. It occupies 1U of rack space.

  1. Align the mounting ears of the PDU with the desired rack unit (U) on your server rack.
  2. Secure the PDU to the rack using appropriate rack screws (not included). Ensure both sides are firmly attached.
StarTech.com RKPW081915 PDU installed horizontally in a server rack

Image: The PDU mounted horizontally within a server rack, demonstrating its 1U form factor and integration with other equipment.

StarTech.com RKPW081915 PDU with dimensions and rack compatibility information

Image: A visual representation of the PDU's height (1U) and cable length (6ft), confirming its compatibility with standard 19-inch racks.

5.3 Innealan ceangail

  1. Ensure the PDU's power/reset switch is in the OFF position.
  2. Plug the power cords of your network and server equipment into the 8 NEMA 5-15R outlets on the rear of the PDU.
  3. Connect the integrated 6-foot power cord of the PDU to a grounded 120V/15A power source.

Video: Demonstrates the installation of a rack-mounted power strip, showing how it integrates into a server rack and connects to devices.

Video: An official product video from StarTech.com showcasing the 8 Outlet Horizontal 1U Rack Mount PDU Power Strip for network server racks, highlighting its surge protection features.

Video: A demonstration of the StarTech 8 Outlet Horizontal 1U Rack Mount PDU, showing its physical attributes and how it fits into a rack setup.

Bhidio: Thar-shealladhview of an 8 Outlet Rack-Mount PDU, detailing its features and benefits for organizing power in a rack system.

Video: A demonstration of a PDU Outlet Horizontal, highlighting its design and functionality for power distribution.

6. Stiùireadh Obrachaidh

6.1 A’ cur cumhachd air/dheth

To power on the connected equipment, press the Power/Reset switch on the front panel to the ON position. To power off, press the switch to the OFF position.

6.2 Comharran LED

  • LED borb (Uaine): When illuminated, it indicates that the surge protection feature is active and functioning. If this LED is off, the surge protection has been compromised, and the unit should be replaced.
  • Ground LED (Green): When illuminated, it indicates that the PDU is properly grounded. If this LED is off, there may be a grounding issue with your power source or the PDU itself.

6.3 Neach-brisidh Circuit

The Power/Reset switch also functions as a circuit breaker. If an overload occurs, the switch will trip to the OFF position, cutting power to all connected devices to prevent damage. To reset the circuit breaker, reduce the load on the PDU and then press the switch back to the ON position.

7. Cumail suas

7.1 Glanadh

To clean the PDU, ensure it is powered off and disconnected from the main power source. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.

7.2 Sgrùdaidhean Cunbhalach

  • Periodically check the Surge and Ground LEDs to ensure they are illuminated, indicating proper function and grounding.
  • Inspect the power cord and connected device cords for any signs of damage or wear.
  • Dèan cinnteach gu bheil a h-uile ceangal tèarainte.

8. A ’dèanamh trioblaid

TrioblaidAdhbhar a dh’fhaodadh a bhith annFuasgladh
Gun chumhachd gu innealan ceangailte.PDU is off or circuit breaker tripped.Ensure the Power/Reset switch is ON. If it tripped, reduce the load and reset the switch.
Ground LED is off.Bunait neo-iomchaidh.Ensure the PDU is plugged into a properly grounded outlet. Check the building's electrical wiring.
Surge LED is off.Surge protection has been compromised.The PDU's surge protection may no longer be active. Replace the unit to ensure continued protection.
Devices are not receiving enough power.Tha cus luchd air an PDU.Reduce the total power draw of connected devices to stay within the 15A limit.

9. Sònrachaidhean

FeartMion-fhiosrachadh
Modail ÀireamhRKPW081915
BrandStarTech.com
Innealan cumhachd iomlan8 x NEMA 5-15R
Input Voltage120 volt AC
Rangachadh làithreach15 Amps
Fad sreang cumhachd6 troigh (1.8 meatairean)
Rack Unit (RU)1U
A' cur suasHorizontal 19-inch Rack Mount
Meudan (LxWxH)19 x 3.76 x 1.68 òirleach (48.26 x 9.55 x 4.27 cm)
Cuideam nì4.85 not (2.2 kg)
Feartan sònraichteMountable, On/Off Switch, Surge Protection, Built-in Circuit Breaker
Casing StuthRugged Steel

10. Barantas agus Taic

This StarTech.com product is backed by a lifetime warranty, ensuring long-term reliability and peace of mind. In addition, free lifetime 24/5 multi-lingual technical assistance is available to help you with any questions or issues you may encounter.

For technical support or warranty claims, please visit the official StarTech.com weblàrach-lìn no cuir fios chun t-seirbheis teachdaiche aca gu dìreach. Cùm do chuidhteas ceannach airson dearbhadh barantais.

© 2024 StarTech.com. All rights reserved.