PCE Instruments PCE-123

Leabhar-làimhe Cleachdaiche Calabradair Pròiseas PCE Instruments PCE-123

1. Ro-ràdh

The PCE Instruments PCE-123 Process Calibrator is a portable, battery-powered device designed for simulating and measuring various electrical signals in industrial and laboratory settings. It functions as a nominal value indicator, allowing users to test and calibrate a wide range of unit parameters and measuring instruments. The calibrator provides electrical output signals including milliampere (mA), millivolt (mV), volt (V), frequency (Hz), and temperature in Celsius (°C) or Fahrenheit (°F).

This manual provides essential information for the safe and effective operation, setup, and maintenance of your PCE-123 Process Calibrator.

2. Fiosrachadh Sàbhailteachd

Please read and understand all safety instructions before operating the PCE-123 Process Calibrator. Failure to follow these instructions may result in injury or damage to the device.

  • Sàbhailteachd dealain: Always ensure the calibrator is properly connected and that test leads are in good condition. Avoid contact with live circuits.
  • Sàbhailteachd bataraidh: Use only the specified battery type. Do not mix old and new batteries or different types of batteries. Dispose of batteries according to local regulations.
  • Suidheachaidhean Àrainneachdail: Operate the device within the specified operating conditions (0 to 50°C; <85% r.h.). Avoid exposure to extreme temperatures, humidity, or corrosive environments.
  • Cumail suas: Refer to the maintenance section for proper cleaning and battery replacement procedures. Do not attempt to repair the device yourself.

3. Pasgan-susbaint

Nuair a dh’fhosglas tu am pasgan, dèan cinnteach gu bheil na nithean gu lèir a tha air an liostadh gu h-ìosal an làthair agus ann an deagh staid:

  • PCE-123 Process Calibrator
  • Cùis Giùlain
  • Type-K Adaptor
  • 6 x 1.5V Batteries (AA type)
  • Test Cables with Alligator Clips
  • Leabhar-làimhe an Neach-cleachdaidh (an sgrìobhainn seo)

4. Toradh thallview

The PCE-123 Process Calibrator features a clear LCD display, a numeric keypad for input, and dedicated function buttons for ease of use. Below is an image of the device with key components highlighted.

PCE-123 Process Calibrator with display showing '04.500 V', a numeric keypad, and test leads connected.

Figure 1: PCE-123 Process Calibrator. This image displays the front of the PCE-123 Process Calibrator. The large LCD screen at the top shows a reading of '04.500 V'. Below the screen is the brand 'PCE' and model 'PCE-123'. The main body features a numeric keypad (0-9) and function buttons, including 'ON/OFF' and 'SHIFT'. Test leads with red and black alligator clips are connected to the bottom right side of the device.

Prìomh fheartan:

  • Easy operation via keypad
  • fèin-ghluasadach ramp function for signal generation
  • Selectable current ranges: 0 to 20mA / 0 to 24mA
  • Input range 0 to 100% for mA, mV, and V signals
  • Audible alarm for 'open' circuit (mA) or 'short circuit' (mV, V) conditions

5. Suidhich

5.1 Stàladh bataraidh

The PCE-123 Calibrator operates on 6 x 1.5V AA batteries (included). To install or replace batteries:

  1. Dèan cinnteach gu bheil an inneal air a chuir dheth.
  2. Lorg còmhdach roinn a’ bhataraidh air cùl an aonaid.
  3. Open the cover and insert the 6 AA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  4. Dùin an còmhdach roinn bataraidh gu tèarainte.

5.2 A’ ceangal uèirichean deuchainn

Use the provided test cables with alligator clips for connecting the calibrator to the circuit or device under test.

  1. Identify the input/output terminals on the PCE-123.
  2. Connect the red test lead to the positive (+) terminal and the black test lead to the negative (-) or common terminal.
  3. Ensure connections are firm and secure before powering on the device or applying signals.

6. Stiùireadh Obrachaidh

The PCE-123 allows for both signal simulation (output) and measurement (input) of various electrical parameters.

6.1 Cumhachd air / dheth

Brùth an AIR/DHETH button to power the calibrator on or off.

6.2 Selecting Measurement/Simulation Mode

Use the mode selection switch or buttons (refer to device markings) to choose between different signal types (mA, mV, V, Hz, °C/°F) and between simulation (output) or measurement (input) functions.

6.3 mA DC Current (Simulation/Measurement)

  • Raointean: 4 to 20mA, 0 to 20mA, 0 to 24mA.
  • Fuasgladh: 1µA.
  • Obrachadh: Select the desired mA range. Use the numeric keypad to input the target current value. The calibrator can simulate current with a maximum load of 1kΩ when powered by 24V.
  • Alarm: An audible beep will sound if there is a short circuit or if the output current exceeds 1mA during certain operations.

6.4 mV / V DC (Simulation/Measurement)

  • Raointean: 0 to 100.00 mV, 0 to 1.0000 V, 0 to 10.000 V.
  • Fuasgladh: 10 µV (mV), 1 mV (V), 1.0000 V (V).
  • Obrachadh: Select the mV or V mode. Input the desired voltage value using the keypad. The calibrator provides power at 1mA for these measurements.
  • Alarm: An audible beep will sound if there is a short circuit or if the output current exceeds 10mV during certain operations.

6.5 Temperature (Simulation/Measurement)

The PCE-123 supports various thermocouple types for temperature simulation and measurement.

  • Seòrsaichean le taic: Type-K, J, E, T.
  • Raointean:
    • K: -200 to 0°C and 0 to 1370°C
    • J: -100 to 0°C and 0 to 760°C
    • E: -10 to 0°C and 0 to 700°C
    • T: -200 to 0°C and 0 to 400°C
  • Fuasgladh: 1°C across the entire range.
  • Obrachadh: Connect the appropriate thermocouple or use the Type-K adaptor. Select the temperature mode and thermocouple type. Input the desired temperature value.

6.6 Frequency (Simulation/Measurement)

  • Raointean: 1 to 125Hz and 126 to 62.5kHz.
  • Fuasgladh: 1Hz (1 to 125Hz), 604 readings (126 to 62.5kHz).
  • Obrachadh: Select the frequency mode. Input the desired frequency value using the keypad.

6.7 Automatic Ramp Gnìomh

The PCE-123 features an automatic ramp function, which allows for gradual increase or decrease of output signals over time. Consult the on-screen menu or specific function keys for activating and configuring this feature.

6.8 Input 0 to 100%

For mA, mV, and V signals, the calibrator supports inputting values as a percentage (0 to 100%) of the selected range, simplifying scaling operations.

7. Cumail suas

7.1 Ath-nuadhachadh bataraidh

When the battery indicator shows low power (5.5V for 150mA consumption), replace all 6 AA batteries as described in Section 5.1. Always use fresh, high-quality batteries.

7.2 Glanadh

To clean the device, wipe the exterior with a soft, damp clò. Na cleachd innealan-glanaidh sgrìobach no fuasglaidhean. Dèan cinnteach nach tèid taiseachd a-steach don inneal.

7.3 Stòradh

When not in use for extended periods, store the PCE-123 in its carrying case in a dry environment, away from direct sunlight and extreme temperatures (-20 to 60°C; <85% r.h.). Remove batteries if storing for more than one month to prevent leakage.

8. A ’dèanamh trioblaid

This section addresses common issues you might encounter with your PCE-123 Process Calibrator.

  • Chan eil an inneal a’ dol air: Thoir sùil air stàladh a’ bhataraidh agus dèan cinnteach gu bheil na bataraidhean ùr.
  • Alarm beep during mA output: This indicates an 'open' circuit or an output current exceeding 1mA. Check connections and the load.
  • Alarm beep during mV/V output: This indicates a 'short circuit' or an output current exceeding 10mV. Check connections and the load.
  • Leughaidhean mì-chruinn: Ensure correct mode selection, proper test lead connections, and that the device is operating within its specified environmental conditions. Calibrate if necessary.

If you experience persistent issues not covered here, please contact PCE Instruments customer support.

9. Sònrachaidhean Teicnigeach

ParamadairSònrachadh
mA DC Current
Raonan4 to 20mA / 0 to 20mA / 0 to 24mA
Fuasgladh1 µA
Cruinneas±0.025% ±3µA
Max Load (24V powered)1kÎ ©
mV / V DC Current
Raonan0 to 100.00 mV, 0 to 1.0000 V, 0 to 10.000 V
Fuasgladh10 µV (mV), 1 mV (V), 1.0000 V (V)
Cruinneas±0.05% ±30 µV (mV), ±0.05% ±3 mV (V), ±0.05% ±300 µV (V)
Cumhachd1mA
Temperature Sensor (Type-K, J, E, T)
Ranges (K)-200 to 0°C and 0 to 1370°C
Ranges (J)-100 to 0°C and 0 to 760°C
Ranges (E)-10 to 0°C and 0 to 700°C
Ranges (T)-200 to 0°C and 0 to 400°C
Fuasgladh1°C (across entire range)
Accuracy (K)±1.1°C and ±0.8°C
Accuracy (J)±0.9°C and ±0.7°C
Accuracy (E)±0.9°C and ±0.7°C
Cruinneas (T)±1.0°C and ±0.8°C
Tricead
Raonan1 to 125Hz and 126 to 62.5kHz
Fuasgladh1Hz (1 to 125Hz) / 604 readings (126 to 62.5kHz)
Cruinneas±0.04Hz
Feartan coitcheann
Taisbeanadh5 position LCD
Cumhachan Obrachaidh0 to 50°C; <85% r.h.
Cumhachan stòraidh-20 to 60°C; <85% r.h.
Cumhachd6 x 1.5V AA batteries (or 1 x 9V battery option)
Caitheamh60mA to 180mA (depending on output)
Comharra Bataraidh5.5V for 150mA
Meudan88 x 168 x 26mm (3.46 x 6.61 x 1.02 òirleach)
CuideamApproximately 2.91 Pounds (with batteries)

10. Barantas agus Taic

PCE Instruments provides a warranty for the PCE-123 Process Calibrator against defects in materials and workmanship. For specific warranty terms, duration, and conditions, please refer to the warranty card included with your product or visit the official PCE Instruments weblàrach.

For technical support, service, or inquiries regarding your PCE-123, please contact PCE Instruments customer service through their official channels. Have your model number (PCE-123) and purchase information ready when contacting support.

PCE Instruments Contact Information:
Feuch an tadhal thu air an PCE Instruments Store on Amazon no an oifigeach aca weblàrach-lìn airson am fiosrachadh conaltraidh as ùire.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.